DigitAx User Guide
Issue code: dgxu4
7-1
7
Parameters
There are two types of parameters
•
•
Variable parameters, denoted by
Prxx
•
•
Bit parameters denoted by
bxx
Variable parameters allow numerical values to be
entered. Bit parameters allow digital settings to be
made.
Both types of parameter can be as follows:
•
Read–write (
R–W
)
•
Read-only (
RO
)
Read–write parameters are programmable by the
user, and the values can be read on the display
(or remotely using a serial communications link).
Read-only parameters are for information purposes;
they cannot be programmed.
Default values
The read–write parameters are programmed during
manufacture with default values which are generally
valid for the size of Drive and motor.
The default values cannot be erased or changed by
the user.
Default table (EPROM)
Not erased by any action.
Always available.
Working table (RAM)
All data is lost when the Drive is
powered-off.
User's table (EEPROM)
Data must be manually saved from RAM.
Last-used data can be recalled.
Last-saved data is automatically sent to
RAM when the Drive is powered-on.
Recall
defaults
b5 = 1
Saving data
b99 = 1
Serial
communications
Data and commands
b1 = 1
Recall last
Pr setting
Figure 7–1
How parameter values are stored and changed
Summary of Contents for DBE1100S
Page 3: ...User Guide DigitAx AC Servo Drive 1 4kW to 22kW Part Number 0415 0008 Issue Number 4...
Page 8: ...DigitAx User Guide Issue code dgxu4 iv...
Page 20: ...DigitAx User Guide Issue code dgxu4 3 8...
Page 28: ...DigitAx User Guide Issue code dgxu4 4 8...
Page 48: ...DigitAx User Guide Issue code dgxu4 5 20...
Page 50: ...DigitAx User Guide Issue code dgxu4 6 2...
Page 54: ...DigitAx User Guide Issue code dgxu4 8 2...
Page 56: ...DigitAx User Guide Issue code dgxu4 9 2...