DigitAx User Guide
Issue code: dgxu4
4-5
4.6 Ferrite
rings
The three conductors of the motor cable from each
Drive must pass twice through two ferrite rings, as
shown in Figures 5–2 and 5–3.
Part number: 4200-0000
Dimension
mm
in
A
105
4
3
/
16
B
24
1
C
62
2
1
/
2
D
28.5
1
1
/
8
E
90
3
5
/
8
Mounting hole diameter
5
3
/
16
Figure 4–2
Dimensions of the ferrite rings
4.7 Control
Keypad
For model size 3, the Control Keypad is a plug-in unit
which can be detached from the Drive for mounting
in a panel. Holes are required in the panel for the
fixing studs and connector which project from the
rear of the Control Keypad housing. Refer to
Figure 4–3.
Area occupied by the Control keypad
Cut out
Dimension
mm
in
A
65.0
2
9
/
16
B
40.0
1
9
/
16
C
26.0
1
1
/
16
D
22.0
7
/
8
E
97.0
3
13
/
16
F
146.5
5
3
/
4
H
167
6
9
/
16
W
114
4
1
/
2
Mounting hole diameter
M4
3
/
16
Figure 4–3
Mounting screw holes and
dimensions of cut-out required
for remote mounting of the
Control Keypad
The Control Keypad on model sizes 1 and 2 cannot
be located remotely from the Drive.
Summary of Contents for DBE1100S
Page 3: ...User Guide DigitAx AC Servo Drive 1 4kW to 22kW Part Number 0415 0008 Issue Number 4...
Page 8: ...DigitAx User Guide Issue code dgxu4 iv...
Page 20: ...DigitAx User Guide Issue code dgxu4 3 8...
Page 28: ...DigitAx User Guide Issue code dgxu4 4 8...
Page 48: ...DigitAx User Guide Issue code dgxu4 5 20...
Page 50: ...DigitAx User Guide Issue code dgxu4 6 2...
Page 54: ...DigitAx User Guide Issue code dgxu4 8 2...
Page 56: ...DigitAx User Guide Issue code dgxu4 9 2...