DW E.S.T. (Elevated Skin Temperature) System
-23-
<Alarm Settings>
Setting
Description
Threshold Time
The time, in milliseconds, the alarm start condition should be maintained. The alarm
will be triggered only after the threshold time conditions are met.
Default : 1000ms (1 second)
Delay Time
The time, in milliseconds, to delay alarm termination when conditions are not
satisfied during alarm occurrence.
Default: 1000ms (1 second)
Interval Time
The time, in milliseconds, to prevent the next alarm from occurring (prevent alarms
too often) after the alarm is closed.
Default: 1000ms (1 second)
<Alarm Digital Output>
Setting
Description
Alarm 1 and Alarm 2 Type,
Mode, Duration (sec)
For each of the available alarm outputs, enter the following. The
default settings listed below are recommended.
Alarm type: NO (normal open)
Mode: Remote control
Duration: 1 second
<Storage Space>
Setting
Description
Automatic file deletion
When the HDD has less than 5% space available, automatically
delete old files first.
Limit alarm storage (GB)
Set a limit to the amount of storage used for alarm storage.
Limit face detection storage
(GB)
Set a limit to the amount of storage used for face detection storage.
8.7. Main Display
The main view in the center of the software shows the camera’s current view, in the layout selected. It also