PS-345XA Reference Manual
3-12
3.4
Checking the Status of the PS-A Being Monitored
3.4.1
Description
Check the status of the PS-A being monitored with the RAS features from the System Monitor screen.
You can also use this screen to check error details.
3.4.2
Setup Procedure
(1)
When the System Monitor starts, the System Monitor icon appears on the task bar. Double-click the Sys-
tem Monitor icon to display the System Monitor screen.
(2)
Click the tab of the item you want to check.
•
For details about the setup procedure, refer to the Setup Guide.
•
When an error occurs, the color of the corresponding tab changes.
•
As for Device No. of SMART, [0] means Master and [1] means Slave.
System Monitor
+5.0V
Pass
+12V
Pass
VcoreA Pass
SEE