Digital PRIORIS ZX Server
Service Procedures
MCS Logistics Engineering - Nijmegen
67
Single Channel SCSI and Single Channel RAID Configuration
To connect devices to a single channel SCSI and single channel RAID configuration, perform the
following:
1) Connect the cables as shown in Figure 3 - 24.
2) If using top 5¼-inch drive bay, connect appropriate power cable to device.
3) Replace and lock side panels.
4) Connect external devices and restore power.
5) Run SCSI
Select
and/or RAID utilities to configure the server.
Refer
Chapter 2, “Server Utilities & Configuration”
and to the SCSI and RAID documentation for
additional configuration information.
NOTE
Server’s with this configuration are shipped with an additional terminator to enable you
to split the storage backplane
Legend
Component
A
Adaptec 7870 narrow/wide SCSI connector (SCSI bus A)
B
Mylex RAID controller (channel 1)
C
Adaptec 7870 narrow/wide SCSI connector (SCSI bus B)
D
Backplane terminator
E
Jumper cable
F
Backplane, 68-pin connector
G
Cable terminator
H
68-pin-to-50-pin adapter cable to top-right drive bay
I
68-pin-to-50-pin adapter cable to CD-ROM drive
J
External SCSI connector
Figure 3 - 24 Single Channel SCSI and Single
Channel RAID Configuration
D E C0 07 32 -2
D
E
F
G
H
I
A
B
J
C