Digital PRIORIS ZX Server
Service Procedures
MCS Logistics Engineering - Nijmegen
51
Installing a SIMM
To install a SIMM, perform the following:
1) Turn off the server.
2) Disconnect external devices, ac power, and monitor power.
3) Unlock and remove left side panel.
4) Remove memory module retaining bracket and memory module (see Figure 3 - 11).
5) Orient notched edge of SIMM (A, Figure 3 -11) so its facing toward center of memory module. The
small notch at middle of bottom edge of SIMM mates with raised area in SIMM socket.
6) Position SIMM at a 45 degree angle relative to socket on memory module (A, Figure 3 - 12).
7) Beginning with bank 1 (sockets 1-4), insert bottom edge of SIMM into socket.
Rock SIMM gently until it completely engages bottom of socket. Tip SIMM upright until both
retaining clips engage (B, C, Figure 3 - 12).
8) Replace memory module (component side down )and secure with retaining bracket.
9) Replace and lock left side panel.
10) Connect external devices and restore power.
11) Run the SCU to configure the server for the additional memory.
Refer to
Chapter 2, “Server Utilities & Configuration”
for information on running the SCU.
Figure 3 - 11 SIMM Orientation
Figure 3 - 12 Installing a SIMM
DEC00735