Digital STARION 400i - 900i PC
Troubleshooting
MCS Logistics Engineering - Nijmegen
59
S
T
A
R
I
O
N
4
0
0
i
-
9
0
0
i
POST and Boot Error Messages
(continued)
Message
Problem
Solution
Keyboard controller error
Keyboard error
Keyboard locked - Unlock key
switch
Keyboard and/or keyboard
controller failed.
Check the keyboard connection.
If the connection is secure, the
keyboard or keyboard controller
might have failed. If the problem
persists, replace the defective
keyboard and/or controller.
Monitor type does not match
CMOS - Run SETUP
Monitor type has been
incorrectly specified.
Run the BIOS Setup utility and set
the correct monitor type.
Operating system not found
The operating system cannot be
found on drive A or drive C.
Run the BIOS Setup utility and
correctly identify drive A or drive
C. Correctly install the operating
system. Refer to the supplied
operating system documentation.
Press <F1> to resume, <F2> to
Setup
This message appears after any
recoverable error message.
Press <F1> to reboot or <F2> to
enter the BIOS Setup utility to
make any necessary changes.
Real time clock error
Real-time clock failed BIOS
test.
Replace real-time clock and then
run the BIOS Setup utility to
restore previous configuration
information.
System cache error - Cache
disabled
RAM cache failed.
Run the BIOS Setup utility and
restore all settings to original
values. If the problem persists,
replace the defective cache
memory.
System CMOS checksum bad -
run SETUP
Battery/real-time clock failed.
Correct the address conflict using
the BIOS Setup utility. If the
problem persists, replace the
battery/real-time clock.
System RAM failed at offset:
nnnn
System RAM failed.
Run the BIOS Setup utility and
restore all settings to original
values. If the problem persists,
replace the defective memory.
System timer error
The computer's timer test failed.
Run the BIOS Setup utility and
restore all settings to original
values. If the problem persists,
replace the defective component.
Shadow RAM Failed at offset:
nnnn
Shadow RAM failed.
Run the BIOS Setup utility and
disable failed shadow memory
region.
System battery is dead -
Replace and run SETUP
Battery/real-time clock failed.
Replace the battery and then run
the BIOS Setup utility to restore
previous configuration
information.
Summary of Contents for FR-902AA-A3
Page 6: ......
Page 8: ......
Page 10: ......
Page 68: ......
Page 72: ......
Page 74: ......
Page 78: ......
Page 80: ......
Page 81: ...Personal Notes...
Page 82: ...Personal Notes...
Page 83: ...Personal Notes...
Page 84: ...Personal Notes...
Page 86: ...Name Title Company Dept Address City State Country...