Digital Dream Standalone Motion Controller DDCS V3.1
DDCS V3.1 Users Manual
Page -79
No Application
()
Raises the Z axis to zero, to
manually change the tool,
stops the program before
pressing the "START"
button, feeds 3 times with
the built-in pshchalko, as a
result, only "T5 cutter 5mm
single-pass" will be written
on the screen. Without
brackets and M110. by 1mm.
G153 Z0
----------
M110(T5 cutter 5mm
single-pass)
The comment character. In any line with a
comment, only the contents of the brackets are
displayed on the screen (increases the space for the
name of the instrument).
Command
Description
Example of use
Description of
the example
Options
M0, M00
Stopping the program, before pressing the
"START" button, is completely the same as
pressing the "PAUSE" button.
Stops the program, before
pressing the "START"
button. Raises the Z axis
and sets the spindle, if it is
set in the settings.
M0
M3, M03
S
Starts the spindle at a speed
of 2000 rpm
M3 S2000
Start spindle rotation with speed S
M5, M05
Stops the spindle
M5
Stop the spindle
M6, M06
T
Replaces the tool with №5
M6 T5
Plays the contents of the T.nc. file Specifies the
tool number for offsets. T specifies the number of
the tool (it can be omitted).
M8, M08
Switch on spindle cooling
M8
Switch on spindle cooling
M9, M09
Switch off spindle cooling
M9
Switch off spindle cooling
M101
No
M101 (open probed function)
G91 G01 Z-50.0 F500.0 (Z axis moves down 500mm,
in this process, if the probe signal appears, the
motion will stop)
M102(turn off the probed function)
G04P0(synchronous)
G90 G92 Z0.0(Set the current workpiece coordinate
system Z-axis coordinate to 0.0)
In order to use the above features, your version
requires Ver: 2018-10-12-102 or later.
Start monitoring the probe signal during the
machining process. If the probe signal appears in
the subsequent movement, the motion will stop.At
this point, you can get the coordinate information
through the macro variable.
Stop the program, before pressing the "START"
button, without moving the axes. Plays a sound
signal (useful for manual tool change).
M102
No
No
No
No
No
turns off the monitoring of the probe signal.
M10
Turn on the coolant pump
М10
Turn on the coolant pump
M11
Turn off the coolant pump
M11
Turn off the coolant pump
M30
It stops the program, before
pressing the "START"
button. Peep 3 times with
built-in peepal
M110
End of the program, cancels all commands and
loops. Do not use immediately after M6.
M105
In order to use the above
features, your version
requires Ver: 2019-04-28-108
or later.
It stops the program, before
pressing the "START"
button. Peep 3 times with
built-in peepal
M105
X-axis homing operation
M106
M106
Y-axis homing operation
M107
M107
Z-axis homing operation
M108
M110
M110
M108
A-axis homing operation
No
No
No
No
No
No