Digital Dream Standalone Motion Controller DDCS V3.1
DDCS V3.1 Users Manual
Page -65
A) The FRO override range is 0~300%, However the real feed speed may be too high for the machine, so we use #41-44
to set a limited speed for safety reason.
B)Please note that the Max. speed cannot be set as Manual control speed.In the controller system we desgined the
algorithm for the speed paln based on the manual control speed,if the max. speed is smaller than manual control
speed,will disturb the algorithem plan.
C) DDCS V3.1 supports Asymmetric Acc/Dec speed.But when the MPG is in control mode(Precision control mode),the
controller will excute each pulse the MPG made,in this situation controller don’t support Asymmetric Acc/Dec speed,when
stop the system also use the Start Acc Speed.
D) In the mode of STEP,actual Start&Stop Acc/Dec speed both are start acc speed.
3) Manual Control Parameters(Totally 20 items)
#41
#42
#43
#44
#45
#46
#47
#48
#100
#101
#102
#103
#263
#264
#265
#266
#2020
#2021
#2022
#2023
99~99999
99~99999
99~99999
99~99999
1~9999
1~9999
1~9999
1~9999
99~99999
99~99999
99~99999
99~99999
9~9999
9~9999
9~9999
9~9999
0~999
0~999
0~999
0~999
X Axis max speed in M_Ctrl mode
Y Axis max speed in M_Ctrl mode
Z Axis max speed in M_Ctrl mode
A Axis max speed in M_Ctrl mode
X axis start Acc in M_Ctrl mode
Y axis start Acc in M_Ctrl mode
Z axis start Acc in M_Ctrl mode
A axis start Acc in M_Ctrl mode
X axis manual control speed
Y axis manual control speed
Z axis manual control speed
A axis manual control speed
X axis stop Acc in M_Ctrl mode
Y axis stop Acc in M_Ctrl mode
Z axis stop Acc in M_Ctrl mode
A axis stop Acc in M_Ctrl mode
Jog-1 moving distance
Jog-2 moving distance
Jog-3 moving distance
Jog-4 moving distance
16000
16000
16000
16000
9
300
300
300
3000
3000
2000
12000
600
600
600
600
0.010
0.100
1.000
10.000
mm/min
mm/min
mm/min
deg/min
mm/s2
mm/s2
mm/s2
deg/s2
mm/min
mm/min
mm/min
deg/min
mm/s2
mm/s2
mm/s2
deg/s2
mm
mm
mm
mm
X,Y,Z,A axis Initial Accelera-
tion Speed in Manual control
mode.
X,Y,Z,A axis Deceleration in
Manual control mode.
X,Y,Z,A axis Feed Speed in
Manual control mode.
Limits the speed if using
FRO to change the speed
4 kinds Jog Moving distance
Para.
Mark
Parameter definition
Default
value
Parameter
Unit
Parameter
Scope
Notes