PART 7: OPTION JUMPER DESCRIPTIONS
Factory default for all jumper settings is in the ON position. To remove a jumper
in the OFF position place the jumper on a single pin for future use
OFF
ON
VSEL J4
This jumper when in the ON position supplies a +12vdc source on the RJ50 input
connector. The hand held controller uses this source for power. Removing this
jumper prevents the +12vdc source from exiting on pin 2 and possibly damaging
other external control devices.
ENSEL J5
When this jumper is in the ON position the external encoder signal connected to
the RJ50 output connector is passed through the print carriage to the RJ50 input
connector. This allows the same encoder signal to drive several print carriages. If
this is not desired remove the jumper
PRSEL J6
When this jumper is in the ON position the external product detect signal
connected to the RJ50 output connector is passed through the print carriage to
the RJ50 input connector. This allows the same product detect signal to drive
several print carriages. If this is not desired remove the jumper
23
EVOLUTION SC
SYSTEM MANUAL Issue 1.1 15 November 2006