1  Product introduction 

     

 

ThermoVu DTM-700 infrared thermal imaging temperature measurement and screening system is 
composed of human body temperature camera, human body temperature measurement blackbody 
and temperature measurement and screening software. Its main feature is non-contact temperature 
measurement, which is suitable for large-scale screening in the scene of train station, airport, bus 
station, hospital and school with large flow of people, so as to realize temperature anomaly warning. 
It  can  be  widely  used  for  medical  temperature  measurement,  real-time  temperature  information 
transmission, accurate detection, rapid diagnosis, etc. 

The core purpose of the temperature measurement and screening system is to screen the target of 
fever  personnel  from  the  normal  temperature  population,  and  then  check  it  again  through  the 
medical temperature measurement instrument. 

2  Site Survey and Commissioning Guide 

ThermoVu DTM-700 infrared thermal temperature measurement and screening system belongs to 

precision temperature measurement and imaging equipment, it has the following requirements for 

engineering exploration application. 

2.1  Scenario requirements 

 

The ambient temperature should be kept relatively constant to avoid obvious changes in the 
body surface temperature of the tested personnel; 

When  the  ambient  temperature  is  within  16-32 

,  the  equipment  supports  accurate 

temperature measurement, and the temperature deviation value is 

±

  0.3 

When  the  ambient  temperature  exceeds  16-32 

,  the  equipment  will  not  be  able  to 

guarantee the accuracy of temperature measurement; 

Indoor scene: It is recommended to use diversion belt (L-type or Z-type) 
Outdoor scene: outdoor scene is not recommended, if necessary, it must be used with tent / 
shelter / sealed shed + diversion belt (L or Z type) 

According to the actual application scenario, it may be necessary to adjust the ambient 
temperature by adding air conditioner or electric heater; 

 

The installation position of the camera shall be well illuminated to avoid backlighting; 

 

The camera monitoring area shall not be interfered by strong heat sources such as strong light 
or sunlight; 

Summary of Contents for ThermoVu DTM-700

Page 1: ...ThermoVu DTM 700 Site Survey and Commissioning Guide Digital Ally Inc All rights reserved Document version V0 4 Release date 2020 04 24...

Page 2: ...n direct laser beam or reflection under any circumstances whether the system is turned on or off otherwise it will cause permanent damage to uncooled infrared thermal system This product is a precisio...

Page 3: ...3 1 Computer host requirements 6 3 2 Computer network configuration 6 3 3 Temperature measurement software installation and device connection 7 3 4 Software version of equipment 10 3 5 Client software...

Page 4: ...easurement and screening system belongs to precision temperature measurement and imaging equipment it has the following requirements for engineering exploration application 2 1 Scenario requirements T...

Page 5: ...ible camera lens needs to be adjusted to the maximum to ensure that it is consistent with the infrared thermal camera s field of view Refer to the Appendix for equipment components and assembly instru...

Page 6: ...nstrument If you want to simulate the test of fever personnel you can choose more than 2 normal temperature personnel to test together and one of them can hold a 38 40 warm mineral water bottle and pu...

Page 7: ...ation and device connection 3 3 1 Software installation 1 First Click Install package Inspection System version V X X X X Please run as administrator 2 Second Click Browse button to select software in...

Page 8: ...3 Click Next and Install button to install 4 After installation wait for the system to configure itself then press any key to continue...

Page 9: ...you can see Inspection System software on the desktop Run the software as administrator 3 3 2 Device connection After opening the software with the administrator s permission wait for the device to c...

Page 10: ...needs to be upgraded to IR V3 05 Mar 20 or later Attention The hardware of the infrared camera of the subsequent equipment is changed and the version is shown as V1 01 03_200303 This version does not...

Page 11: ...ference person needs to be standing at a distance of 5m from the camera for calibration standing on the left and right side of the screen in turn First move the yellow calibration points on the infrar...

Page 12: ...and include the whole round target of the blackbody in the blackbody box Then right click the blackbody box to turn on the blackbody and the blackbody temperature should be 37 consistent with the act...

Page 13: ...ll in the average indoor ambient temperature usually 25 in the Environment Click Apply to complete the setting Attention 1 The ambient temperature compensation function is used to compensate the tempe...

Page 14: ...on 3 6 1 Logging in to visible camera Not necessary by default If it is necessary for you to log in to visible camera to check configuration Open IE browser log in IP of 192 168 1 13 then log in user...

Page 15: ...ot alarm 1 Check whether the alarm threshold is set correctly Generally the alarm threshold is set to 37 3 Check whether the alarm threshold is set too large 2 No temperature measurement if no face is...

Page 16: ...e outdoor environment temperature rises sharply and the body surface temperature rises too much with the seasons change it may interrupt the manual compensation of the temperature in the client Genera...

Page 17: ...lid floating point value when running the client At present the client software only adapts to the regional format corresponding to English By default the regional format of the computer is automatica...

Page 18: ...he probability of recurrence of this problem is very low At present there are only avoidance methods but no specific solution which belongs to product defects 4 Appendix 4 1 Equipment components The e...

Page 19: ...pod and tripod accessories For example Note the appearance of tripod actually delivered may be different which does not affect the actual use and the actual arrival shall prevail 2 Take off the fixed...

Page 20: ...is as shown in the figure 5 The distance between camera and blackbody is about 2 5M 4 2 2 Line connection 1 Connect the two ends of the output cable to the camera and DC12V power adapter 2 Plug the tw...

Page 21: ...ware and run it as an administrator 4 3 2 Visible camera software upgrade 1 Open IE browser log in IP of 192 168 1 13 then log in user name of admin when the password is 123456 If the device has been...

Page 22: ...4 3 3 Infrared thermal camera upgrated 1 2 3 4 5 6...

Reviews: