At this time, you need to configure the new password of the device in the configuration interface.
➢
Enter “Device config”-> “Modify device” interface
➢
Change the password to the one you reset at 3.6.1 in “IPCamera pwd” this column
➢
Click "Apply" to complete the setting.
3.5.2 Position calibration
➢
Enter “System para”-> “Position calibration” interface
➢
A reference person needs to be standing at a distance of
5m
from the camera for calibration
(standing on the left and right side of the screen in turn).
➢
First, move the yellow calibration points on the infrared and visible images to the same
position on the lower left corner of the image ((such as knee position).
➢
Then move the green calibration points on the infrared and visible images to the same
position on the upper right corner of the image (such as the raised palm).
➢
After all four points have been moved, click "Apply" to complete the setting.