Command|8 Guide
56
Fader Utilities
Fader Calibration
Use this routine to return the motorized, touch-
sensitive faders to their factory calibration set-
ting.
To reset the faders:
1
Press the F1 Utility switch to enter Utility
mode.
2
Press the Channel Select switch that corre-
sponds to Fader.
3
Press the Channel Select switch that corre-
sponds to Fadcal.
Do not touch the faders, as the fader routine be-
gins immediately and moves the faders through
their range of travel. The lower row of the LCD
shows fader resolution while the test is in pro-
cess.
Faders park at the bottom of the fader paths
when recalibration is complete.
4
Press the Channel Select switch that corre-
sponds to Exit.
5
Press the F1 Utility switch to exit Utility mode.
Fader Test
Use this test to troubleshoot the mechanical el-
ements of the Command|8 faders.
To test fader resolution:
1
Press F1 Utility, if necessary, to enter Utility
mode.
2
Press the Channel Select switch that corre-
sponds to Fader.
3
Press the Channel Select switch that corre-
sponds to FadTst. Do not touch the faders.
4
Press the Select switch on Channel 8 to stop
the test.
5
Press the F1 Utility switch to exit Utility mode.
Group Test
Use this test to compare performance of each
Command|8 fader as both a group master and
slave.
To test fader group resolution:
1
Press the F1 Utility switch to enter Utility
mode.
2
Press the Channel Select switch that corre-
sponds to Fader.
3
Press the Channel Select switch that corre-
sponds to Group.
4
Select Group by pressing the channel 3 Select
switch.
5
One by one, touch and move each fader. The
other seven faders follow, and the LCD displays
resolution for each fader as they move through
their range.
6
Press the Channel Select switch that corre-
sponds to Exit.
7
Press the F1 Utility switch to exit Utility mode.