34
7.4.2.3
Configurable functions (via DS2)
a) Waiting time after passage:
Selection:
DS2-P1, DS2-P2.
This feature allows selecting the waiting time before closing the door after a valid
passage. Times can be 0.5 seconds, 1.25 seconds, 2 seconds or Smart Speed.
In the Smart Speed option, the system measures the passage speed and calculates the
time for a person to go over the blockage in safety. The blockage area goes to the
maximum distance that the door can reach plus 100mm, indicated in the hatched area
below. In the Smart Speed function, minimum and maximum times are, respectively, 0.5
and 10 seconds. The SmartSpeed function operates correctly since the passage speed is
constant.
b) Validation accumulation (Access queue):
Selection:
DS2-P3
With this function, it is possible that several clearances in sequence are counted so that a
user queue may pass without the door closing. To activate it, the next person in line must
clear their passage while the person in front of them is still passing (before door begins
closing).
c) Door movement speed
Selection:
DS2-P4
Allows configuration of door speed during cycles of opening and closing the passage.
Slow speed movement corresponds to 30% of the normal speed.
Tower
90°
170
(6,692")
90°
285
(11,220")
385
(15,157")
70
(2,755")
Long door
Short door