Safety Considerations

Turning Point Gates

Safety Considerations

                 - 2 -

12. Gates shall 

not

 swing into public access areas.

13. Manual gate latches shall 

not

 be installed on any automated gate. Locks or security devices that function with

the automated gates are acceptable.

14. Do not increase the potentiometer setting to compensate for a damaged gate.

15. Gate operator controls must be located a minimum of 6’ (1.83 m) from any

moving portion of the gate in the open or closed position.

16. Gate operator controls must be placed where they cannot be reached from

outside the secured area.

17. Gate operator controls must be in the line of sight when the gate is moving.

Reset switch is on the control box.

18. Gate operator controls box must have a security feature to prevent

unauthorized use.

19. Properly installed gates shall meet the standard requirement of UL 325 and

ASTM  F 2200 as applicable for gates in Class I, II, III, or IV. 

Check local

codes for any further requirements.

20. Warning signs (see figure 2) shall be positioned on both sides of each gate and

easily visible. The signs shall be attached to the gates. (Signs are supplied with

the gate)

21.

Do NOT weld or alter the pivoting end of the gate.

 Electrical parts are

encased in the rounded tube and welding on, or altering it will void the

warranty

22. Most local emergency responder departments (Police, Fire, and Ambulance) have their specific requirements

for the emergency opening of the gate. 

Check with the local departments for their requirements

. The

circuit board in the control box has a terminal for emergency opening.

23.

Keep these instructions in your files for any future references.

Less than 16” when fully open

16” or more when fully open

Figure 1

Entrapment Protection

Required

Gate Does NOT need

Entrapment Protection

Gate

Post

Large Pillar

or Structure

4” or Less

from Pivot

Entrapment Protection

Not Required

Gate Needs Entrapment

Protection

More than

4” from Pivot

Pivot Point

Pivot Point

Gate

Hinge

Gate

Hinge

Figure 2

Fence, Building or other Stationary Object

Fence, Building or other Stationary Object

Gate

Gate

Summary of Contents for Turning Point

Page 1: ...TM TM TM TM TM TM Installation and Operators Manual...

Page 2: ......

Page 3: ...pointgateopeners com Safety Considerations 4 5 Installation Instructions 6 13 Tools Needed 6 Pre Installed Considerations 6 Gate Installation Instructions 6 8 Control Box Installation Instructions 9 1...

Page 4: ...e to manual use while the gate is moving 8 Do not add any items to the gate that are not approved for use with this gate system 9 Automated gates are divided into 4 classes per ASTM F2200 and UL 325 s...

Page 5: ...cal codes for any further requirements 20 Warning signs see figure 2 shall be positioned on both sides of each gate and easily visible The signs shall be attached to the gates Signs are supplied with...

Page 6: ...NOTE Check local codes for any specific requirements when routing 12 volt electrical underground 3 Position the bottom hinge of the gate onto the gatepost If this is to be a double drive system start...

Page 7: ...move until it stops b If the gate is moving in the direction opposite what you want to open the gate continue to run the gate till it stops c Remove the power source after the gate stops and manually...

Page 8: ...the gate with top adjustable hinge mount see Figure 8 a To raise the outer edge of the gate turn the top adjustment counter clockwise b To lower the outer edge of the gate turn the top adjustment clo...

Page 9: ...nal marked GATE 2 Again polarity is not critical see section C Control Box Wiring Functions o and p 6 Attach the charging source s to the SOLAR AC terminal A 12 volt AC AC transformer supplied with co...

Page 10: ...e positive wire to the side and the negative wire to the side c Switch System power switch is used to turn the system on and off It will also reset the system Upon power up the system is reset and wil...

Page 11: ...al for gate 2 of a double drive system 3 In the control box cover lid is a small circuit board This is the wireless transmitter receiver see figure E3 It is connected to the circuit board with a three...

Page 12: ...signed to close 4 seconds after the gate close cycle is complete The gate open cycle will also not begin till the power bolt has unlocked Polarity is critical for the power lock a Wires must be run th...

Page 13: ...he electromagnet can be attached to the post where the gate strikes In such a situation attach the magnet receiver on the gate aligned with the electromagnet on the post e Run the wire supplied with t...

Page 14: ...ery Voltage low 1 Readjust potentiometer sensitivity 2 Charge battery and check charging system Gate will not open using wireless transmitter or key pad transmitter 1 Power switch for system not on 2...

Page 15: ...ed areas Approve with this signature date detach and fax this portion of your Operators Manual to 574 546 5099 Property Owner Signature ____________________________________________ Date _____________...

Page 16: ...ct of God The manufacturer will not be responsible for any labor charges incurred in the removal or replacement of defective parts In case of failure due to defective material or workmanship during th...

Page 17: ...___________________________________________________ YOUR _______________________________________________ WARRANTY Location of gate installation if not the same as above address Where Installed Are you...

Page 18: ...P O Box 241 Bremen IN 46506 Phone 574 546 5999 Fax 574 546 5099 www turningpointgateopeners com Place Stamp Here Digger Specialities Inc P O Box 241 Bremen IN 46506...

Page 19: ......

Page 20: ...99705 07 11 11...

Reviews: