Gate Installation Instructions

 

  

                           - 3 - 

 

Tools Needed: 

 

Power Drill and drill bit (Bit size and type 

is dependent on gate mounting surface 

 

Hex Bit Socket set or Hex wrenches 

 

Tape Measure 

 

Level   (a string level is beneficial when 

installing a double drive system.) 

 

Wire Strippers 

 

Small Screwdriver 

Pre-Installation Considerations. 

 

DSI will engineer the size of the post needed to 

support the gate.  Attaching the gate to anything other 

than the post recommended by DSI is not  advised. 

Locate where you will place the control panel. You will 

need to run appropriately sized wires from the control 

panel to the bottom hinge of each gate. Approximately 

16’ of wire is supplied with each gate. As mentioned 

previously do not position the gate so that it will swing 

into public access areas. Follow all local codes and 

ordinances when positioning the Turning Point gates. 

Gates that are to have a magnetic or power bolt lock 

system should have the wires routed in the gate to the 

location of the device prior to hanging the gate. Wires 

should terminate the gate at a bottom hinge location. 

A. Gate Installation Instructions. 

1.

 

Lay out a plan for the positioning of the 

gate and the control box. Make sure that 

you will have a minimum of 6’ from any 

moving part of the gate to the control box. 

The control box must be located within 

direct view of the gate.  

2.

 

Dig a trench, deep enough to prevent wires 

from damage, from the control box to the 

bottom hinge of each gate. (

NOTE:

 Check 

local codes for any specific requirements 

when routing 12-volt electrical 

underground.) 

3.

 

 Position the bottom hinge of the gate onto 

the gatepost. 

(If this is to be a double drive 

system start with the gate on the highest 

ground.)

 The top of the hinge bracket is to 

be positioned at a point  3/8” above the 

desired bottom of the gate. Be sure the 

hinge is perpendicular. Level the top of the 

hinge mount bracket. If the bracket is not 

kept perpendicular and level the gate will 

not function properly. Attach bracket with 

appropriate fasteners. (See figure 1) 

 

 

4.

 

Loosen the collar clamp on the bottom 

bracket to allow the pivot end of the gate to 

fit into the collar.  

5.

 

Feed the 12-volt, 2 wire, jacketed power 

cable at the pivot end of the gate (inside the 

pipe) through the hole in the bottom center 

of the bottom bracket. There is an angle 

bracket beside the hole . The wire will feed 

through the hole easily if the wire is guided 

in at the top of the bracket and pulled from 

the bottom with the wire rubbing against 

the bottom of the angle bracket 

simultaneously.  (See figure 2)   

 

 

 

 

 

 

 

 

 

 

  

6.

 

Set the galvanized pipe onto the bottom 

bracket so that the pipe seats fully into the 

collar. Be sure the wire is not pinched 

between the collar and the pipe. (See figure 

3) Support the outer edge of the gate to 

keep it close to level. Also support the gate 

to keep it from tipping to the left or right of 

the bracket. (See figure 4) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adjusting 

Bolt 

Pull Here 

Figure 2 

Figure 1 

 

Galvanized Pipe

 

Figure 3 

Collar

  

Clamp 

Level

  

Attachment  

Holes (4)      

 

Wire

 

Bottom 

                                                                                                   

Bracket

 

 

Wire

 

Figure 4 

Figure 4 

Bottom

 

Bracket 

Block or person 

supporting gate

  

Pull Here

 

Bottom Bracket

 

To Pull 

wrap 

under  

angle 

bracket

 

Gatepost 

Gate Installation Instructions

6

Summary of Contents for Turning Point

Page 1: ...TM TM TM TM TM TM Installation and Operators Manual...

Page 2: ......

Page 3: ...pointgateopeners com Safety Considerations 4 5 Installation Instructions 6 13 Tools Needed 6 Pre Installed Considerations 6 Gate Installation Instructions 6 8 Control Box Installation Instructions 9 1...

Page 4: ...e to manual use while the gate is moving 8 Do not add any items to the gate that are not approved for use with this gate system 9 Automated gates are divided into 4 classes per ASTM F2200 and UL 325 s...

Page 5: ...cal codes for any further requirements 20 Warning signs see figure 2 shall be positioned on both sides of each gate and easily visible The signs shall be attached to the gates Signs are supplied with...

Page 6: ...NOTE Check local codes for any specific requirements when routing 12 volt electrical underground 3 Position the bottom hinge of the gate onto the gatepost If this is to be a double drive system start...

Page 7: ...move until it stops b If the gate is moving in the direction opposite what you want to open the gate continue to run the gate till it stops c Remove the power source after the gate stops and manually...

Page 8: ...the gate with top adjustable hinge mount see Figure 8 a To raise the outer edge of the gate turn the top adjustment counter clockwise b To lower the outer edge of the gate turn the top adjustment clo...

Page 9: ...nal marked GATE 2 Again polarity is not critical see section C Control Box Wiring Functions o and p 6 Attach the charging source s to the SOLAR AC terminal A 12 volt AC AC transformer supplied with co...

Page 10: ...e positive wire to the side and the negative wire to the side c Switch System power switch is used to turn the system on and off It will also reset the system Upon power up the system is reset and wil...

Page 11: ...al for gate 2 of a double drive system 3 In the control box cover lid is a small circuit board This is the wireless transmitter receiver see figure E3 It is connected to the circuit board with a three...

Page 12: ...signed to close 4 seconds after the gate close cycle is complete The gate open cycle will also not begin till the power bolt has unlocked Polarity is critical for the power lock a Wires must be run th...

Page 13: ...he electromagnet can be attached to the post where the gate strikes In such a situation attach the magnet receiver on the gate aligned with the electromagnet on the post e Run the wire supplied with t...

Page 14: ...ery Voltage low 1 Readjust potentiometer sensitivity 2 Charge battery and check charging system Gate will not open using wireless transmitter or key pad transmitter 1 Power switch for system not on 2...

Page 15: ...ed areas Approve with this signature date detach and fax this portion of your Operators Manual to 574 546 5099 Property Owner Signature ____________________________________________ Date _____________...

Page 16: ...ct of God The manufacturer will not be responsible for any labor charges incurred in the removal or replacement of defective parts In case of failure due to defective material or workmanship during th...

Page 17: ...___________________________________________________ YOUR _______________________________________________ WARRANTY Location of gate installation if not the same as above address Where Installed Are you...

Page 18: ...P O Box 241 Bremen IN 46506 Phone 574 546 5999 Fax 574 546 5099 www turningpointgateopeners com Place Stamp Here Digger Specialities Inc P O Box 241 Bremen IN 46506...

Page 19: ......

Page 20: ...99705 07 11 11...

Reviews: