Perform the following steps to start the system recovery and warm-up.
1. Press and release the system power push button to turn off the system. It
may take several minutes for the system to completely turn off
2. Close upper chassis and the door of the safe to allow the system to
warm-up according to the required minimum recovery times.
3. After the required minimum recovery time, press and release the system
power push button to turn on the system. The on/off indicator lights up.
After the system has completely powered up, the operating system of
the system starts loading.
4. If the system has completely powered up, (power indicator light is on) put
the system in a maintenance mode.
5. Close upper chassis and the door of the safe to allow the system to
warm-up according to the required minimum recovery times (refer to
Table 3-1).
6. Follow your institution's procedures to place the system in service.
Table 3-1 System Exposure and Recovery Times
Outside Temperature
Range Description
Maximum Exposure
and Recovery Times
+5° to +1° C
Maximum exposure (any upper chassis or door of the safe open)
40 minutes
(+41° to +33° F)
Minimum recovery if 40 minutes are exceeded (warm-up)
15 minutes
0° to -6° C
Maximum exposure (any upper chassis or door of the safe open)
30 minutes
(+32° to +21° F)
Minimum recovery if 30 minutes are exceeded (warm-up)
20 minutes
-7° to -12° C
Maximum exposure (any upper chassis or door of the safe open)
20 minutes
(+19° to +10° F)
Minimum recovery if 20 minutes are exceeded (warm-up)
30 minutes
-13° to -24° C
Maximum exposure (any upper chassis or door of the safe open)
10 minutes
(+9° to -11° F)
Minimum recovery if 10 minutes are exceeded (warm-up)
60 minutes
-25° to -34° C
Maximum exposure (any upper chassis or door of the safe open)
5 minutes
(-13° to -30° F)
Minimum recovery if 5 minutes are exceeded (warm-up)
6 hours
3-4
Copyright ©Diebold, Incorporated (7/2015) - All Rights Reserved
Copyright ©Diebold Nixdorf, Inc. (4/2017, 9/2018) - All Rights Reserved
TP-821815-001C