OPERATOR’S MANUAL
GAC® 2100 Grain Analysis Computer (Blue, Gray, Agri Models)
11001-1688-201609
INSTRUMENT SETUP 57
control lead busy sense has three polarity choices: IGNORE,
ACTIVE (+), or ACTIVE (-).
The DTR (20) (data terminal ready) line notifies the GAC 2100 that the
printer (computer) is turned ON. The Control Lead DTR Sense has two
states: IGNORE or ACTIVE.
2. Edit the configuration of the COM2 Port screen.
Control Lead Setup
menu displays seven items but only three lines can be edited.
– MODE : TRANSMIT ONLY or AUTO ANSWER
(Blue model)
– RTS (4): ON (+) or AUTO
– DSR (6): IGNORE or ACTIVE
3. After editing is complete, select the
Previous Page
key to return to the
Communications
menu for the next selection.
Figure 46
Accessing COM Control Lead Setup Screen
SELECT ITEM NUMBER
(NEXT PAGE: STATUS)
ENTER ACCESS CODE: __
COM1 (DCE) CONTROL LEAD SETUP
BUSY (11) : IGNORE
DTR (20) : ACTIVE
TO SELECT,
SETUP MENU
1: CLEAR COUNTER
2: ID OPTIONS
3: OUTPUT OPTIONS
4: EDIT ACCESS CODE
5: DATE/TIME MENU
6: LABELS MENU
7: COM MENU
8: SERVICE MENU
COMMUNICATIONS MENU
COM1 (DCE) CONTROL LEAD SETUP
1: COM PORT SELECT
2: COM1 FORMAT
3: COM1 DATA SETUP
4: COM1 CONTROL
5: non-active
6: COM2 FORMAT
7: COM2 DATA SETUP
8: COM2 CONTROL
TO CHANGE
SELECT ITEM NUMBER
<more>
COM2 (DTE) CONTROL LEAD SETUP
MODE : TRANSMIT ONLY
RTS (4) : ON (+) RLSD (8) : IGNORE
CTS (5) : ACTIVE DTR (20) : ON (+)
DSR (6) : IGNORE RI (22) : IGNORE
TO SELECT,
TO CHANGE
OR
COM1
PORT
SCREEN
COM2
PORT
SCREEN
Previous Page key