OPERATOR’S MANUAL
GAC® 2100 Grain Analysis Computer (Blue, Gray, Agri Models)
11001-1688-201609
24 MEASURE MOISTURE
Figure 17
Example of Factors
NEXT PAGE VIEW
After the grain analysis is complete and the moisture content displays,
<more> appears on the lower right corner of the screen indicating another
page is available.
Press the
Next Page
key to view the calculated values (D1, D2, D3 and D4)
determined from the grain measurement (
Figure 18
). These values are
relatively unimportant to the operator but are important to service
personnel. A general definition of each value is as follows:
D1 -
Conductance measurement to indicate grain surface moisture.
D2 -
Capacitance measurement to indicate internal grain moisture.
D3 -
Weight measurement to indicate grain weight.
D4 -
Temperature to indicate grain temperature.
Blue model-
Below the D calculations, the TEST WEIGHT OFFSET (as applicable)
appears. This value is programmed on the
Setup
menu (refer to Instrument
Setup). The current date, time, and sample ID also display.
Figure 18
Next Page Typical Calculated D-Values
CUSTOMER ID
54
VEHICLE NUMBER
4
CODE
382
LOAD WEIGHT
19535
WHEAT HRW
ID: AB1234
ENTER RESULTS FOR THE FOLLOWING:
960518
D1: nnnn
D2: nnnn
D3: nnnn
D4: nnnn
TEST WEIGHT OFFSET: +0.4 LB/BU
DATE: 05/18/16
ID: 12
TIME: 16:42:20
Blue model
only
Next Page Key