4.3. Display / failures
Below on the display you can read the actual working hours of the machine and you can check if the antifreeze
filling function is active.
Centrally you can read the working pressure and the output temperature.
Left on top the engine speed setting will be displayed (100% is similar to the max. adjusted pressure, in example
below: 250 Bar. When the engine speed setting is 50%, the working pressure will visualize 125 bar).
For info: configuration of your cleaner must have option steam + option automatic engine speed setting !
Right on top the setting temperature will be displayed.
Setting: 0°C= burner off & 1°C or more= stand- by temperature.
It can be that the actual temperature has a higher value than the setting temperature, the burner will not
work until the actual temperature is lower than the setting temperature.
Temperature settings
Determine experimentally which engine speed (spray pressure) and at which temperature the object best can be
cleaned without damaging it. Protein-containing material, rubber or synthetic material: knob not higher than 50°C.
For the other settings the most diverge materials and/or machines will be cleaned.
Therefore, there are no fixed settings to be displayed.
High cleaning temperatures
A cleaning temperature of more than 95°C can only be obtained by reducing the number l/min produced by the
high pressure pump. By placing the throttle lever to the left ( min. pressure, min flow) or by reducing the engine
speed setting on the display one reduces the number of l/min.
The temperature shall increase maximum until the set value is reached. If the flow is low, the flow switch shall put
the burner out of use, to prevent that the temperature will increase.
On the left & right side you can check the tank levels (fuel & water) (option- when choosing level measuring).
When the level will decrease below 20%, the display will visualize the level in red color.
Above 20%, the filling level will be displayed in green color.
Right below there’s an indication if the burner is active or not (through indication of flame/ strikethrough flame).
If you move the control stick 1x up & 1x down, the burner will turn off. Temperature indication then becomes 0 ° C.
The burner hours are visible on the home screen if pushed on the clock key (see photo at the bottom right).
These burner hours will only be visible at the time of pushing the (clock) key.