2 - Mode d’emploi - Conseil d’installation

7

2.3    Installation place

- The unit should be installed in a properly ventilated space; it requires an air intake of at least 2 m3/h .kW of thermal

capacity.

- The unit should be installed in compliance with the safety regulations applicable in the country of installation.

2.4    Positioning

2.5    Connection to the gas system

2.6.1  Incoming pressure check (PE)

- This unit may be installed individually or mounted together with other units from the same range of products.

- This unit is not suitable for encasing.

- A minimum clearance of 10 cm to partition walls should be maintained. Should this clearance be smaller or if the

partition or floor material is flammable, installing thermal insulation is mandatory.

- The unit’s gas supply should have the characteristics and pressure shown in Table II.

- Gas pressure is measured at the initial pressure outlet with the burner on.

- The unit has been tested and fitted for operation with the type of gas indicated on the external sticker plate.

* N.B. Should the supply pressure vary by more than +10% of the nominal pressure, it is advisable to install a

pressure regulator upstream of the unit to ensure the nominal pressure.

- Connection to the gas supply should be performed using metal piping of an appropriate cross section; an approved

shutoff cock must be fitted upstream.

- After connecting the gas supply, use soap water to check for leaks at pipe joints.

The pressure is measured with a pressure gauge from 0 to 80 mbar 

(accuracy at least 0.1 mbar).

The pressure connection is on the sit block.

Close the gas valve.

Unscrew the screw (A) of the «IN» pressure tap.

Fit the silicone rubber hose into the manometer.

Open the gas valve.

Turn on the burner and raise the «dynamic» pressure upstream. Close 

the gas valve.

Reassemble the screw (A) with a gas seal washer and check for leaks 

with soapy water.

2.6.2  Control of operation using liquid gas

2.7    Discharge of exhaust flue products under a draft hood

- Check whether the fitted nozzles comply with the indications in Table 2 (see p. 07).

- Check whether the incoming pressure complies with the indications in Table 2 (see p. 07).

- Make sure that the LPG gas system has two pressure regulators of adequate capacity and that the evaporation capa

city is sufficient.

- Please also refer to the publication “Installation Regulations and Characteristics of LPG Systems”.

The gas unit should be installed in rooms enabling the discharge of flue products in compliance with the installation 

standards.

The ventilation system should be permanently activated in accordance with the national and regional standards in force.

A

Summary of Contents for MECA-FRYER 3B

Page 1: ...Mod MIKA 3 MC Production code MECA FRYER 3B 01 2018 ...

Page 2: ...MECA FRYER MANUAL FRYERS ...

Page 3: ...ng technician 08 Adjusting the settings 09 Table 1 Gas Pressure Values and Categories in Various Countries 10 Table 2 Setting the Pressure and Consumption 10 Conversion for operation with a different type of gas 11 Replacing the nozzle of the main burner 11 Setting the primary air at the main burner 11 User instructions 12 Igniting the unit 12 Turning the unit off 13 Upkeep recommendations 13 Drai...

Page 4: ...n how to use it and have read this user manual For any repairs contact only customer service centres authorised by the manufacturer and ask for genuine parts Failure to comply with these instructions may jeopardize the safety of the unit Never aim high pressure water jets at the unit to wash it Never cover any openings heat extraction vents or exhaust vents THIS APPLIANCE MUST BE INSTALLED BY AN A...

Page 5: ...0 4 80 G25 m h 1 85 3 70 4 55 Injector G20 G25 Ø 3 4 3 4 3 4 G30 G31 Ø 2 15 2 15 2 15 Burners number 1 2 3 Pressure mbar G20 12 12 12 Pressure mbar G25 15 15 15 Pressure mbar G31 20 20 20 Air adjustment no no no Electrical connection 23v 16A 50Hz 23v 16A 50Hz 23v 16A 50Hz Pilot burner G20 G25 Ø 20 20 20 G30 G31 Ø adjustable adjustable adjustable 612 876 30 63 526 212 670 930 1455 Stainless steel A...

Page 6: ...mer numéro pin pin number 230V 50 Hz 0 5 A Qn Hs V kW kW m h G20 G25 20 25 mbar 15 1 16 61 1 6 G31 37 mbar 12 6 13 86 0 51 G25 25 mbar 15 1 16 61 1 6 G30 30 mbar 12 6 13 86 0 51 G31 30 mbar 12 6 13 86 0 51 G20 25 mbar 15 1 16 61 1 6 G30 G31 IE 28 30 37 mBar A NL II2L3B P II2E 3P GB BE C GC p 12 6 13 86 0 51 II2E3 Qn Hi Dit toestel dient te worden geinstalleerd conform de geldende regels en mag enk...

Page 7: ...o the gas supply should be performed using metal piping of an appropriate cross section an approved shutoff cock must be fitted upstream After connecting the gas supply use soap water to check for leaks at pipe joints The pressure is measured with a pressure gauge from 0 to 80 mbar accuracy at least 0 1 mbar The pressure connection is on the sit block Close the gas valve Unscrew the screw A of the...

Page 8: ...on procedure may result in hazardous situations for which TEKNO LAM disclaims all responsibility If installation is not performed by an authorised installer the warranty will be invalidated In all cases damaged or worn parts must be replaced with genuine spare parts and must be installed by an authorised installer Any parts to be replaced under warranty must be returned to us no later than 8 days ...

Page 9: ...njector if it not intended for the type of gas that you will use If the utilised gas is different from the type indicated on the data plate see p 3 please proceed as shown in the following picture NEVER SET A PRESSURE VALUE THAT IS HIGHER THAN SPECIFIED 2 In case of problems with the pilot burner such as the flame often going out adjust the pilot light as illustrated in the picture 1 Remove the ca...

Page 10: ...25 25mb G31 37mb G20 20mb G25 25mb G31 37mb G20 20mb G25 25mb G31 37mb Pressure settings at each burner in mbar 12 15 20 12 15 20 12 15 20 12 15 20 Higher heating value HHV max kW 16 61 16 61 13 86 33 22 33 22 27 72 49 3 49 3 41 58 66 44 66 44 55 44 Lower heating value LHV max kW 15 1 15 1 12 6 30 2 30 2 25 2 45 3 45 3 37 8 60 4 60 4 50 4 Number of burners 1 1 1 2 2 2 3 3 3 4 4 4 Gas consumption i...

Page 11: ...ed gas type as indicated in Table 2 p10 Shut the gas valve upstream of the unit 3 2 Setting the primary air at the main burner Start the unit according to the user instructions Check for leaks using soapy water Ignite the pilot flame according to instructions and check it To check the primary air setting at the main burners the X clearance must be set exactly as shown see image The primary air is ...

Page 12: ...and never above the MAX mark Refer to the Technical Data Table p02 to determine the tank capacity MAX MIN FILLING THE BASKET The amount of food to be placed into the basket depends on the cooking method It is most important to avoid a sharp drop in temperature when dipping the food into the oil In any case oil temperature should never drop below 160 C Cooking small amounts of food for the right le...

Page 13: ...fill the tanks above the lowest level In case of failure always call an authorised technician or retailer Fryers are equipped with a safety thermostat that trips if the oil overheats and turns off the appliance To restart the appliance you need to reset the thermostat This must be done by qualified service personnel who will also check the cause of tripping After about two hours of operation disco...

Page 14: ...tes but when I release the button see the relevant description after 10 15 seconds the flame goes out by itself Generally this indicates a defective thermocouple component you MUST HAVE IT REPLACED Your appliance has a rock solid design and robustness according to optimum safety manufacturing standard My appliance keeps turning itself off Is your appliance properly connected There should be a mini...

Page 15: ...ainless steel items with a cloth soaked in paraffin oil applying a protective film Periodically air out the room COOKING TANKS Empty the oil tanks by draining the oil off through the drain cock A down to the drip pan Afterwards clean the tanks using suitable detergent Do not scrape or scratch the bottom Rinse abundantly with water to remove any traces of detergent STAINLESS STEEL ITEMS Stainless s...

Page 16: ...LLE 1 2 60 59b 59c 59a DÉTAIL H ECHELLE 1 4 52b 52a 52c 11 9 DÉTAIL I ECHELLE 1 1 13b Echelle 1 50 A3H création mardi 18 novembre 2014 10 30 37 matière nom client Bertrand Mecafryer piecse de rechanges conseillées n plan Vérifié par n A Rev Description mardi 7 mars 2017 11 54 47 B Auteur Echelle 1 50 A3H création mardi 18 novembre 2014 10 30 37 matière nom client n commande n plan Vérifié par n A ...

Page 17: ... O9051 bulbe bleu régulation bloc sit 52c G116B G116B G116B bulbe vert thermomètre 54 G131 FRITEUSES G131 FRITEUSES G131 FRITEUSES bruleur circulaire TGP 15 55 F015 F015 F015 support bruleur 59a F018 F018 F018 thermocouple 59b G115 FRITEUSES G115 FRITEUSES G115 FRITEUSES veilleuse 3 flammes 59c G122 FRITEUSES G122 FRITEUSES G122 FRITEUSES bougie d allumage 60 O9086 O9086 O9086 support veilleuse 63...

Reviews: