DIAMOND AIRCRAFT
DA 20/100 Flight Manual
Emergency Procedures
Doc # 202-100-VLA
9 March, 2001
Page
DOT Approved
3 - 18
3.3.14 Instrument Panel Lighting Failure
1.
Rocker Switch, map light
ON
2.
Rocker Switch, I-panel lighting
Cycle Rocker Switch OFF - ON
3.
Dimming Control
Turn fully clockwise
4.
Internal Lighting Circuit Breaker.
If tripped, reset
5.
If NOT Successful
Expect electrical power failure.
Use Flashlight
Ref. 3.3.9
3.3.15 Tachometer failure
Operation at T/O (5 minute) power:
1. Airspeed
Do not exceed 110 KIAS
Operation at maximum continuous power:
1. Propeller Speed Control Lever
Ensure lever is at least ½ inch (10mm)
(measured at slot) aft of full forward position.
Engine will now be operating at, or below,
maximum continuous power.
NOTE
With propeller speed control lever at least ½ inch (10mm) aft of full forward position, the Max. Permissible
Continuous RPM (2260 RPM) cannot be exceeded at any throttle setting and airspeed. However,
maximum engine power may not be available.