Troubleshooting 5

For parts or assistance, call Diamond Customer Service at 

1-800-265-7241

SYMPTOM

PROBABLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t start or run. Blown fuse.

If blown, replace with fuse of proper size.

Low line voltage.

If voltage under recommended minimum, check size of wiring from
main switch on property. If OK, contact power company or hydro
authority.

Defective motor.

Replace pump.

Defective float switch.

Replace pump.

Float obstructed.

Remove obstruction.

Pump starts and stops

Backflow of water from piping.

Install or replace check-valve.

too often.

Faulty float switch.

Replace pump.

Pump won’t shut off.

Defective float switch.

Replace pump.

Restricted discharge 

Remove pump and clean pump and piping.

(obstacle in piping).
Float obstructed.

Remove obstruction.

Pump operates but

Low line voltage.

If voltage under recommended minimum, check size of wiring from 

delivers little or 

main switch on property. If OK, contact power company or hydro 

no water.

authority.

Something caught in impeller.

Replace pump.

Worn or defective parts or

Replace pump.

plugged impeller.
Check valve installed without

Drill a 1/16" - 1/8" (1.6mm - 3.2mm) dia. hole in the discharge pipe  

vent hole.

between the pump discharge port & the check valve.

NOTICE:

These pumps have no serviceable parts inside case. Opening case will ruin pump. For obstructions or blockages

of the impeller replace the pump.

Hazardous voltage. Can shock, burn or kill

. Unplug pump before attempting to clean or work on pump.

Summary of Contents for 309986V

Page 1: ...on or maintenance assistance Call 1 800 265 7241 2004 253P6460 2 10 04 OWNER S MANUAL Submersible Sump Pumps Mod 309986V 309996V 293 Wright St Delavan WI 53115 Phone 1 800 265 7241 Fax 1 800 925 3486...

Page 2: ...at FLOTEC s option subject to the terms and conditions set forth below Three 3 Year Warranty If within three 3 years from original consumer purchase any 1 2 HP Submersible Sump Pump shall prove to be...

Page 3: ...electrick shock Can burn or kill To reduce risk of electric shock pull plug before servicing Pump is supplied with a grounding conductor and grounding type attachment plug Be sure it is con nected onl...

Page 4: ...pe or a properly grounded metallic raceway or ground wire system Do not cut off ground pin 8 If pump discharge line is exposed to outside sub freezing atmosphere portion of line exposed must be instal...

Page 5: ...switch Replace pump Restricted discharge Remove pump and clean pump and piping obstacle in piping Float obstructed Remove obstruction Pump operates but Low line voltage If voltage under recommended m...

Page 6: ...6 For parts or assistance call Diamond Customer Service at 1 800 265 7241...

Page 7: ...allation ou l entretien Composer le 1 800 265 7241 2004 253P6460 10 2 04 NOTICE D UTILISATION Pompes submersibles pour puisard Mod 309986V 309996V 293 Wright St Delavan WI 53115 T l phone 1 800 265 72...

Page 8: ...au choix de DIAMOND conform ment aux termes et conditions stipul s ci dessous Garantie de trois 3 ans Si dans les trois 3 ans compter de la date d achat par le consommateur d orig ine une pompe d ass...

Page 9: ...nt 115 volts monophas et est muni d un cordon d alimentation approuv 3 conducteurs et d une fiche 3 broches dont une de mise la terre Risques de secousses lectriques Risques de br lures voire de mort...

Page 10: ...cousses lectriques de br lures voir de mort La pompe doit tou jours tre raccord e la terre sur un tuyau d eau mis la terre une canalisation m tallique ad quatement mise la terre ou un circuit lectriqu...

Page 11: ...d fectueux Remplacer la pompe Flotteur obstru Enlever l obstruction La pompe d marre et Circulation contre courant de Poser un clapet de non retour ou le remplacer s arr te trop souvent l eau dans le...

Page 12: ...6 Pour obtenir des pi ces ou de l aide appeler le Service la client le Diamond en composant le 1 800 265 7241...

Reviews: