background image

For parts or assistance, call Diamond Customer Service at 

1-800-265-7241

General Information / Installation

3

ELECTRICAL & SWITCH
SPECIFICATIONS

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give many
years of trouble-free service when correctly installed,
maintained, and used. However, unusual circumstances
(interruption of power to the pump, dirt/debris in the
sump, flooding that exceeds the pump’s capacity, elec-
trical or mechanical failure in the pump, etc.) may pre-
vent your pump from functioning normally. To prevent
possible water damage due to flooding, consult your
retailer about a secondary AC sump pump, a DC backup
sump pump, and/or a high water alarm. See the
“Troubleshooting Chart” in this manual for information
about common sump pump problems and remedies. For
more information, see your retailer or call Diamond cus-
tomer service at 1-800-265-7241.
1. Know the pump application, limitations, and poten-

tial hazards.

2. Disconnect power before servicing.
3. Release all pressure within system before servicing

any component.

4. Drain all water from system before servicing.
5. Secure discharge line before starting pump. An unse-

cured discharge line will whip, possibly causing per-
sonal injury and/or property damage.

6. Check hoses for a weak or worn condition before

each use, making certain that all connections are
secure.

7. Periodically inspect sump, pump and system compo-

nents. Keep free of debris and foreign objects.
Perform routine maintenance as required. 

8. Provide a means of pressure relief for pumps whose

discharge line can be shut-off or obstructed.

9. Personal Safety:

a. Wear safety glasses at all times when working

with pumps.

b. Keep work area clean, uncluttered and properly

lighted – replace all unused tools and equipment.

c. Keep visitors at a safe distance from work area.
d. Make workshop child-proof – with padlocks, mas-

ter switches, and by removing starter keys.

10. When wiring an electrically driven pump, follow all

electrical and safety codes that apply.

11.

This equipment is only for use on 115 volt (single
phase) and is equipped with an approved 3-conduc-
tor cord and 3-prong, grounding-type plug.

Risk of electrick shock. Can burn or

kill.

To reduce risk of electric shock, pull plug before

servicing. 
Pump is supplied with a grounding conductor and
grounding-type attachment plug. Be sure it is con-
nected only to a properly grounded grounding-type
receptacle.
Where a 2-prong wall receptacle is encountered, it
must be replaced with properly grounded 3-prong
receptacle installed in accordance with codes and
ordinances that apply.

12. All wiring should be performed by a qualified 

electrician.

13. Make certain power source conforms to require-

ments of your equipment.

14. Protect electrical cord from sharp objects, hot sur-

faces, oil, and chemicals. Avoid kinking cord. Replace
or repair damaged or worn cords immediately.

15. Do not touch an operating motor. Modern motors

can operate at high temperatures.

16. Do not handle pump or pump motor with wet hands

or when standing on wet or damp surface, or in
water.

Risk of electrick shock. Can burn or kill. 

If

your basement has water or moisture on floor, do not
walk on wet area until all power has been turned off. If
shut-off box is in basement, call electric company or
hydro authority to shut-off service to house, or call your
local fire department for instructions. Remove pump and
replace it. Failure to follow this warning can result in
fatal electrical shock.
17. Do not use this pump in water where fish are present.
18. This pump has not been investigated for use in

swimming pool areas.

Oil on the pump or in the sump may indicate motor
leakage and an electrical shock hazard. Turn off power
and check pump for oil leakage from impeller area.
Replace pump if it leaks.

INSTALLATION

1. Install pump in a sump pit with a minimum 

diameter of 10" (254 mm). Sump depth should be
18" (457 mm). Construct sump pit of tile, concrete,
steel or plastic. Check local codes for approved
materials.

2. Install pump in pit so that switch operating mecha-

nism has maximum possible clearance.

3. Pump should not be installed on clay, earth or sand

surfaces. Clean sump pit of small stones and gravel
which could clog pump. Keep pump inlet screen clear.

NOTICE: 

Do not use ordinary pipe joint compound

on plastic pipe. Pipe joint compound can attack
plastics.

Motor

Individual

*Switch Setting

Motor Full Load

Branch Circuit

in inches (mm)

Series

HP

Amps

Req. (Amps)

On

Off

309986V

1/3

2.6

15

8"

3-1/2"

(203)

(89)

309996V

1/2

3.0

15

8"

3-1/2"

(203)

(89)

Summary of Contents for 309986V

Page 1: ...on or maintenance assistance Call 1 800 265 7241 2004 253P6460 2 10 04 OWNER S MANUAL Submersible Sump Pumps Mod 309986V 309996V 293 Wright St Delavan WI 53115 Phone 1 800 265 7241 Fax 1 800 925 3486...

Page 2: ...at FLOTEC s option subject to the terms and conditions set forth below Three 3 Year Warranty If within three 3 years from original consumer purchase any 1 2 HP Submersible Sump Pump shall prove to be...

Page 3: ...electrick shock Can burn or kill To reduce risk of electric shock pull plug before servicing Pump is supplied with a grounding conductor and grounding type attachment plug Be sure it is con nected onl...

Page 4: ...pe or a properly grounded metallic raceway or ground wire system Do not cut off ground pin 8 If pump discharge line is exposed to outside sub freezing atmosphere portion of line exposed must be instal...

Page 5: ...switch Replace pump Restricted discharge Remove pump and clean pump and piping obstacle in piping Float obstructed Remove obstruction Pump operates but Low line voltage If voltage under recommended m...

Page 6: ...6 For parts or assistance call Diamond Customer Service at 1 800 265 7241...

Page 7: ...allation ou l entretien Composer le 1 800 265 7241 2004 253P6460 10 2 04 NOTICE D UTILISATION Pompes submersibles pour puisard Mod 309986V 309996V 293 Wright St Delavan WI 53115 T l phone 1 800 265 72...

Page 8: ...au choix de DIAMOND conform ment aux termes et conditions stipul s ci dessous Garantie de trois 3 ans Si dans les trois 3 ans compter de la date d achat par le consommateur d orig ine une pompe d ass...

Page 9: ...nt 115 volts monophas et est muni d un cordon d alimentation approuv 3 conducteurs et d une fiche 3 broches dont une de mise la terre Risques de secousses lectriques Risques de br lures voire de mort...

Page 10: ...cousses lectriques de br lures voir de mort La pompe doit tou jours tre raccord e la terre sur un tuyau d eau mis la terre une canalisation m tallique ad quatement mise la terre ou un circuit lectriqu...

Page 11: ...d fectueux Remplacer la pompe Flotteur obstru Enlever l obstruction La pompe d marre et Circulation contre courant de Poser un clapet de non retour ou le remplacer s arr te trop souvent l eau dans le...

Page 12: ...6 Pour obtenir des pi ces ou de l aide appeler le Service la client le Diamond en composant le 1 800 265 7241...