DISPLAY PANEL
The status display shows various color coded status icons that will light up when communicating the
operator. Pay close attention to the status icons and color if they appear.
Status Icon
Description
Parking Brake Switch – Green icon displays when the parking brake is
applied.
Low Fuel Level – Red icon will display when fuel level is low.
Low Battery Voltage – Orange icon will display when battery voltage is
low.
Maintenance Required – Black icon will display when a required
maintenance milestone is reached.
Active Fault – Red icon is visible if the controller receives a DM1 message
with a red lamp command.
Engine Exhaust High Temperature Lamp – Red icon displays during active
DPF regeneration when the DPF outlet temperature is greater than
450°C/842°F and post engine fuel injection is occurring.
DPF Regeneration set to Inhibit – Yellow icon displays when the machine
or the operator has inhibited regeneration.
Regeneration Needed – Yellow icon will display solid to request an
automatic regeneration when regeneration is set to inhibited. Icon will
become red when regeneration is required.
High Coolant Temperature – Yellow icon will display solid when the
coolant temperature rises above normal.
Neutral – Green icon displays when the transmission is in neutral.
The fault message display shows descriptive indication of any current fault conditions
associated with the saw.
24