DISPLAY PANEL
3. Regen Settings
a) This menu will display a screen showing the Diesel Particulate Filter (DPF)
regeneration choices available as well as the time since the last regeneration was
completed. The machine is factory set to allow for un-inhibited regenerations of the
DPF. It can be set to inhibit the regeneration process by selecting the option. There
is also an option to request a regeneration from this menu. See the Maintenance
section of this manual for additional information regarding the DPF regeneration
process.
Display Features (Home Screen)
During engine operation, all essential parameters are monitored from the “Home” screen through a
series of displays and gauges. There are two displays associated with the “Home” screen:
•
Status Display - Located at the top center of the display screen
•
Fault Message Display - Located at the bottom center of the display
There are six digital gauge displays associated with the “Home” screen. Three are fixed gauges and
three are dynamic gauges:
•
Fixed Gauges – Located above the fault message display.
1. Battery Voltage (V)
2. Fuel Tank Level (%)
3. Coolant Temperature (°F / °C)
•
Dynamic Gauges – Large gauge located in the middle of the display. Only one gauge appears
at a time. The individual gauges are toggled through the use of the “Display Mode” function
key.
1. Blade Speed (RPM)
2. Engine Torque (ft-lbs / Nm)
3. Engine Speed (RPM)
23