Patriot Series Single Tank Product Manual
pg. 22
11. Control Error Codes
Problem
Possible Cause
Solution
E1, Err-1001, Err-101 =
Control unable to sense
motor movement
Motor not inserted full to engage
pinion, motor wires broken or
disconnected
Disconnect power, make sure motor is
fully engaged, check for broken wires, and
make sure two-pin connector on motor is
connected to the two pin connection on
the PC board labeled MOTOR. Press NEXT
and REGEN buttons for 3 seconds to
resynchronize software with piston
position or disconnect power supply from
PC board for 5 seconds and then
reconnect.
PC board not properly snapped
into drive bracket
Properly snap PC board into drive bracket
and then press NEXT and REGEN buttons
for 3 seconds to resynchronize software
with piston position or disconnect power
supply from PC board for 5 seconds and
then reconnect.
Missing reduction gears
Replace missing gears
E2, Err-1002, Err-102 =
Control valve motor ran
too short and was unable
to find the next cycle
position and stalled
Foreign material is lodged in
control valve
Open up control valve and pull out piston
assembly and seal/stack assembly for
inspection. Press NEXT and REGEN
buttons for 3 seconds to resynchronize
software with piston position or
disconnect power supply from PC board
for 5 seconds and then reconnect.
Mechanical binding
Check piston assembly and seal/stack
assembly, check reduction gears, check
drive bracket and main drive gear
interface. Press NEXT and REGEN buttons
for 3 seconds to resynchronize software
with piston position or disconnect power
supply from PC board for 5 seconds and
then reconnect.
Main drive gear too tight
Loosen main drive gear. Press NEXT and
REGEN buttons for 3 seconds to
resynchronize software with piston
position or disconnect power supply from
PC board for 5 seconds and then
reconnect.
Improper voltage being delivered
to PC board
Verify that proper voltage is being
supplied. Press NEXT and REGEN buttons
for 3 seconds to resynchronize software
with piston position or disconnect power
supply from PC board for 5 seconds and
then reconnect.
Summary of Contents for DCS6-120-125
Page 1: ...Patriot Series Single Tank Product Manual pg 0 Patriot Single Tank Product Manual...
Page 16: ...Patriot Series Single Tank Product Manual pg 15...
Page 17: ...Patriot Series Single Tank Product Manual pg 16...
Page 18: ...Patriot Series Single Tank Product Manual pg 17 9 System Specifications...
Page 19: ...Patriot Series Single Tank Product Manual pg 18...