19
Installation & Configuration
PC-9042 Portable Anechoic Chamber
Manual Control Knobs
Your system is equipped with two knobs which enable you to manually rotate each
axis of the system. Be careful, as the labels warn you, do not turn when powered off or
when under holding current. This can lead to incorrect positioning and/or other issues
with the encoder. When the knobs are used while the machine is powered off, these
movements obviously can not tracked by the software.
Limit Switches
Your DC202 turntable is equipped with limit switches which prevent the turntable
positioner from over-rotating. Over-rotation will cause cables to wrap and destroy
them.
The diagram below illustrates the +/- ~185 degree movement capable with the system
Note (DC402 shown below)
Miscellaneous Notes
Gimbal (Phi) Manual
Control Knob
Turntable (Theta)
Manual Control Knob
Position:
ON
Position:
OFF