D IAMOND AIRCRAFT
HK 3 6 TS
FLIGHT MANUAL
Normal Procedures
5. Slip the horizontal stabilizer onto the rearward bol t s .
6. Screw in the fastening bol t to the stop with an 8 mm hexagon key
applying moderate hand force ( approximately 6 Nm / 4 . 5 f t . lb s ) .
7 . Check the horizontal stabil izer for secure attachment , and inspect
load transmis sion of elevator control system .
8. Install the pi tot tube .
9 . Apply water resistant adhesive tape to the gap between the
horizontal stabilizer and the vertical stabi l i z er .
4.2.8
stabilizer
To remove the horizontal stabil izer reverse the procedure .
4.3
DAILY INSPECTION
W.AR.N I NG
Master switch OFF , ignition OFF!
1 . Fuel tank drain check : drain o f f about 1 / 8 l iter ( approx .
1 / 8 US quart )
of fuel using a transparent drain cup
( see
paragraph 7 . 10 ) . Inspect for dirt or water .
NOTE
In order to prevent the water deposited in the tank
from dispersing, the airplane must not be agitated
prior to the drain check .
Revision No .
Date
Source
Doc . No .
I ssue
Page No .
3.01 . 0 6
Jan 1996
4 - 6