Operating Manual
BG-180EC
Fault diagnosis
2
9.1 Fault diagnosis – grinding machine
Prior to any repair works on the machine or its drives the
machine must be secured against unintentional switching-on.
Put the machine to its Safety off position
.
Fault Possible
cause Remedy
Excessive
vibration
Imbalance due to worn or
broken grinding tools.
PU-belt is to tight
Replace all worn or
broken parts
release the tension of
the upper belt
Unusual
noises
Defective bearing
Wrong tension of the V-
belt
Defective motor bearing
Debris deposit on the
coupling
Check the bearing on
the axle drive shaft and
replace if necessary.
Check the tension of
the V-belt, replace the
V-belt if necessary
Change the motor
Clean the coupling
Reduced or
no grinding
performance
Grinding tools have
reached the maximum
permissible wear
Inappropriate grinding tool
for the application
Too low tension of the
V-belt
Replace the worn parts
Replace the grinding
tools with appropriate
grinding tools for the
surface to be treated
Re-tension the V-belt
Summary of Contents for BG-180EC
Page 1: ...Operating Manual BG 180EC ...
Page 2: ......
Page 4: ......
Page 8: ...Operation Manual BG 180EC Technical Data 4 1 5 Machine type designation ...
Page 40: ...Operating Manual BG 180EC Operation 6 Notes ...
Page 60: ...Operating Manual BG 180EC Electrics 4 8 3 Electric circuits diagram of E01532 110V 28 0A 50Hz ...
Page 70: ...Operating Manual BG 180EC Fault diagnosis 4 Notes ...
Page 71: ...BG 180EC Operating Manual Spare Parts 1 Contents Chapter 10 10 1 Spares Parts List BG 180EC ...
Page 74: ...Operating Manual BG 180EC Spare Parts 4 Fig 10 2 ...