© Dialog Semiconductor 2008. All rights reserved.
All brand and product names are trademarks or service marks of their respective owners. Printed in Europe.
DA852X-UG02-608 Page 21 of 47
User Guide Release 2.0
DA852X E Ink Evaluation Kit
Display Controllers
3.5
File Formats
3.5.1
The Configuration Files
Plain text configuration files (.ini) are used to store all settings that will be restored when the program is started.
DA852X.ini, stored in the Data subdirectory, contains some basic setups such as the device index selected, and the list
of user-added projects. This ini file is editable if the program is not running.
[Setup]
offline=0
Device_index = 3
[User Projects]
User project8 = "cascade,128"
User project12 = "numerics,30"
User project13 = "memory,32"
If the line “offline=0” is changed to “offline=1”, this flags to the software that hardware is not attached.
Filename
.ini, stored in the subdirectory
filename
in the Data directory is used to store settings specific to that project.
This includes the number of outputs, the location of the Map and Image files, timing parameters, and lists of sequences
and alphanumerics.
The file allows the project to be reopened with all parameters and settings intact from previous sessions.
[Setup]
Device = 64
ImageFile = " 520-1264_rev01_070410.BMP"
Clock Period = 5
Blank Period = 350
Standby Delay = 20
Standby Period = 420
Backplane = 63
Sequence Update Rate = 0.1
FillColour = 16711680
Fill = 1
Waveform Select = 7
MapFile = "
520-1264_rev01_070410.map"
Invert = 0
Number Offset File = Number_defs.txt"
[Alphanumerics]
Alpha1 = "a"
Alpha2 = "b"
Alpha3 = "c"
[Waveform 3]
T0 = 280
T1 = 280
T2 = 280
P0 = 280
P1 = 280
P2 = 280
P3 = 280
P4 = 280
P5 = 280
[Waveform 2]
P0 = 280
[Waveform 4]
T0 = 280