DLEV1
Operating Instructions
- 20 -
6 Specifications
6.1 Functions
PE Pre-Test
Yes
PP Simulation
NC, 13A, 20A, 32A & 63A
CP States
A
B
C
D
EV not connected
EV connected and not ready
CEV connected, non-vented &
ready to charge
EV connected, vented & ready to
charge
CP Error
“E”
PE Error (Earth Fault)
Charge On/Off
Charge On/Off
6.2 Outputs (for test purposes only)
Measuring Terminals
(L1, L2, L3, N & PE)
Max. 250V CAT II 300V, Max. 10A
Mains Socket
Max. 250V.CAT II 300V, allowed
current max.10A.
Note:
Do not load mains socket
simultaneously with measuring terminals
Mains Socket Protection
Fuse 10A/250V (5x20mm)
CP
Signal
Output
Terminals
Approx. ± 12V, CAT O (Under normal
conditions). In the case of incorrect
wiring or error of the charging station,
these terminals may become a hazard
≥ up to max. CAT II 300V against PE.
6.3 General Features
Input Voltage
Up to 250V [Single phase system]/up
to 430V (Three phase system),
50/60Hz, max 10A.
Type 2 Test Cable
AC charging mode 3, suitable to
IEC62196-2 type 2 socket outlet or
fixed cable with vehicle connector
(Type 2, 7P three-phase).
Type 1 Test Cable
AC charging mode 3, suitable to
IEC62196-2 type 1 or SAE J1772
with vehicle connector (Type 1, 5P
single-phase).
Weight
Adaptor Approx. 470g, Adaptor with
connector plug Approx. 950g
Adaptor Dimensions
(L)110mm x (W)50mm x (H) 230mm
Safety
IEC/BS EN 61010-1:2010 IEC/ BS
EN
61010-2-030:2010