32
DHOLLANDIA
1)
Remove the power pack cover and set aside.
2)
Route the (-) ground and (+) battery cables through the
provided grommets located above the hydraulic reservoir.
3)
The (+) battery cable must go to the open terminal on the
motor solenoid.
4)
The (-) cable must go to the (-) negative terminal on the
electric motor. Use a second wrench so the ground terminal
does not turn in its place.
Turning the terminal in place will
damage the grounding inside the motor and render it
inoperable
.
5)
Electrical controls can be run into the power pack by
removing the rubber shroud as shown above. Connections
can then be wired to the orange connection block. Refer to
instructions in section 11 on page 26.