43
ST102-CS
www.dfi.com
NCT6116D HW Monitor
This section displays the hardware health monitor.
► Smart Fan Function
Please refer to the following pages.
Case Open
Enable or disable the case open detection function.
► Smart Fan Function
Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc.
Version 2.20.1271. Copyright (C) 2019 American Megatrends, Inc.
Pc Health Status
Smart Fan Function
Case Open
System temperature
CPU temperature
CPU_Fan Speed
VBAT
VCORE
VDDQ
5V
+12V
Advanced
[Disabled]
: +29
o
C
: +36
o
C
: N/A
: +3.072 V
: +0.864 V
: +1.200 V
: +5.116 V
: +12.056 V
Smart Fan function
setting
→←:
Select Screen
↑↓:
Select Item
Enter: Select
+/- : Change Opt.
F1: General Help
F2: Previous Values
F9: Optimized Defaults
F10: Save & Exit
ESC: Exit
Aptio Setup Utility - Copyright (C) 2019 American Megatrends, Inc.
Version 2.20.1271. Copyright (C) 2019 American Megatrends, Inc.
Advanced
→←:
Select Screen
↑↓:
Select Item
Enter: Select
+/- : Change Opt.
F1: General Help
F2: Previous Values
F9: Optimized Defaults
F10: Save & Exit
ESC: Exit
Pc Health Status
CPU Smart Fan Control
CPU Smart Fan Mode
Boundary 1
Boundary 2
Boundary 3
Boundary 4
Speed Count 1
Speed Count 2
Speed Count 3
Speed Count 4
[SMART FAN IV]
30
40
50
60
35
60
80
100
CPU smart Fan Mode
select
CPU Smart Fan Mode
Enable or disable the system smart fan. When set to “Manual mode”, fan speed
will not be controllable according to different system temperatures. Instead, a
“Manual PWM Setting” field will be displayed to configure at which speed the fan
will always be fixed regardless of system temperature.
When “CPU Smart Fan Mode” is set to “SMART FAN IV”, the following fields will
appear.
Boundary 1 to Boundary 4
Set the boundary temperatures that determine the fan speeds accordingly, the
value ranging from 0-127oC. For example, when the system temperature reaches
Boundary 1 setting, the fan speed will be turned up to the designated speed of
the Fan Speed Count 1 field.
Speed Count 1 to Speed Count 4
Set the fan speed, the value ranging from 1-100%, 100% being full speed.
The fans will operate according to the specified boundary temperatures above-