15
ST102-CS
www.dfi.com
LCD/Inverter Power Select
JP9 is used to select the power level of LVDS LCD inverter connector.
Panel Power Select
Important:
Before powering-on the system, make sure that the power settings of JP8 match the
LCD panel’s specification. Selecting the incorrect voltage will seriously damage the
LCD panel.
JP8 is used to select the power supplied with the LCD panel.
JP8
▲
1-2 On: +12V
▲
3-4 On: +5V
▲
5-6 On: +3.3V
(default)
1
6
4
2
5
3
1
6
4
2
5
3
1
6
4
2
5
3
▲
2-3 On: +5V
▲
1-2 On: +12V (default)
JP9
3
1
2
3
1
2