background image

IOLITE®

TECHNICAL REFERENCE MANUAL

IOLITE® V21-1

1

Summary of Contents for IOLITE

Page 1: ...IOLITE TECHNICAL REFERENCE MANUAL IOLITE V21 1 1 ...

Page 2: ...2 3 7 1 Additional instructions for troubleshooting with EtherCAT devices 23 4 System Overview 25 4 1 Main features 26 4 1 1 Redundant Bus Systems 26 4 1 2 Input Slots and Amplifiers 27 4 1 3 Redundant Power Supply 28 4 1 4 Feedback Monitoring 28 4 2 System specifications 29 4 3 Enclosure Overview 31 4 3 1 IOLITE Cabinet Mount Chassis 31 4 3 1 1 IOLITE R12 Cabinet Mount Chassis Renders 31 4 3 1 2 ...

Page 3: ...e 51 4 3 2 8 IOLITE Multi channel Renders 53 4 3 2 9 IOLITE Multi channel Dimension 53 4 3 2 10 IOLITE Multi channel Connectors 54 4 3 2 10 1 IOLITE Multi channel PWR IN 54 4 3 2 10 1 IOLITE Multi channel PWR OUT 55 4 3 2 10 2 EtherNET in 55 4 3 2 10 3 EtherNET out 56 4 3 3 IOLITE Single channel device 57 4 3 3 1 IOLITE Single channel Renders 57 4 3 3 2 IOLITE Single channel Dimensions 58 4 3 3 3 ...

Page 4: ...0 16xLV TBLOCK Connector Wiring diagram 88 5 2 4 10 1 16xLV Voltage 88 5 3 LA Low Amperage 89 5 3 1 LA Specifications 90 5 3 2 LA BNC Connector 91 5 3 2 1 8xLA BNC Connector Pinout 91 5 3 2 2 8xLA BNC Connector Wiring diagram 92 5 3 2 2 1 8xLA Current 92 5 3 3 LA T2A2f Connector 93 5 3 3 1 8xLA TBLOCK Connector Pinout 93 5 3 3 2 8xLA TBLOCK Connector Wiring diagram 94 5 3 3 2 1 8xLA Current 94 5 4...

Page 5: ...r 120 5 7 2 1 TH Miniature Thermocouple Connector Pinout 120 5 7 2 2 TH Miniature Thermocouple Connector Wiring diagram 121 5 7 2 2 1 TH Voltage 121 5 7 2 2 2 TH Temperature 121 5 8 CNT Counter Module 123 5 8 1 CNT Specifications 124 5 8 2 CNT LEMO L1B7f Connector 125 5 8 2 1 CNT LEMO L1B7f Connector Pinout 126 5 9 AO Analog output module 126 5 9 1 IOLITE 16xAO 127 5 9 2 IOLITE 1xAO 127 5 9 3 AO S...

Page 6: ...2 2 1 EtherNET IN 139 7 Accessories 140 8 Appendix 141 8 1 Glossary and abbreviations 142 9 Warranty information 146 9 1 Calibration 147 9 2 Support 147 9 3 Service repair 147 9 4 Restricted rights 147 9 5 Copyright 147 9 6 Trademarks 148 10 Safety instructions 148 10 1 Safety symbols in the manual 149 10 2 General Safety Instructions 149 10 2 1 Environmental considerations 149 10 2 2 Product End ...

Page 7: ...options A description of the connection variants and the pin assignments on the inputs and outputs A comprehensive introduction to the configuration of the modules using DewesoftX Detailed technical data Specifications etc 2 1 Legend The following symbols and formats will be used throughout the document Important Gives you important information about a subject Please read carefully Hint Gives you ...

Page 8: ...cal reference manual 2 2 2 DewesoftX User Manual The DewesoftX User Manual document provides basics and additional information and examples for working with DewesoftX and certain parts of the program The latest version of the DewesoftX tutorials can be found here https download dewesoft com list manuals brochures software manuals In the Software Manuals section click the download link of the Dewes...

Page 9: ... stick included in the shipment your PC with Windows 10 Note older versions like Windows 7 may also work 3 1 Software installation For optimal working we recommend that you install the latest version of DewesoftX If you already have DewesoftX installed please check if a newer version is already available You can either check on the website under Support Downloads DewesoftX section or directly in s...

Page 10: ...side of the ethernet cable to the LAN port of PC You can find advanced connections in chapter 3 3 1 4 Connection of IOLITE R12 Connection of IOLITE R12 standalone device to PC IOLITE R8 First connect the power supply cable PS 120 L1B2f to the PWR IN 2 pin LEMO 1B male connector Then connect L1T8f RJ45 1M cable LEMO side to the IN connector of BUS 1 on the IOLITE R8 back panel Finally connect the o...

Page 11: ... advanced connections in chapter 3 3 2 4 Connection of IOLITE R8 Connection of IOLITEi multi channel standalone device to PC IOLITEi single channel First connect the power supply cable RJ 45 to the IOLITEi Power junction Then connect RJ 45 cable to the IN connector Finally connect the other side of the other side RJ45 to the LAN port of the PC You can find advanced connections in chapter 3 3 2 4 C...

Page 12: ...l show up in the DewesoftX settings Click on the Options button at the top right and then on the Settings item in the pop up to open the DewesoftX settings dialogue DewesoftX settings In the Devices section you can see the connected IOLITE slices When you select one of them the properties pane at the right will show the related data e g Serial number Firmware version etc IOLITE V20 1 12 153 ...

Page 13: ...e corresponding channel in the Channel setup grid will automatically be selected This also works the other way around when you select a channel or multiple channels in the setup grid the corresponding connectors in the image will be highlighted The sampling rate will be set for all connected IOLITE slices of course only up to the max sampling rate of the individual slices Channel setup IOLITE R12 ...

Page 14: ...IOLITE TECHNICAL REFERENCE MANUAL Channel setup IOLITE R8 IOLITE V20 1 14 153 ...

Page 15: ...ewesoftX consult the Manual To open the manual press the F1 button or click on the Options button and then select Manual from the pop up menu Help Manual When DewesoftX has started up you will be in Measure mode and see the Setup files list or you can create a New setup Click on Ch setup on the right of Setup files to switch to the Channel setup mode In the channel setup you can see a preview of t...

Page 16: ...d the mouse button and move the mouse down to channel 8 then release the mouse button and all channels will be selected this is shown by the black rectangle around the buttons Then you can click into the selected region to toggle Used Unused for all channels at once The selected channels will also be highlighted in the small preview image of the device When you press the Setup button of a channel ...

Page 17: ...e domain with a good time resolution you should sample 10 to 20 times faster than the frequency of the signal that you want to measure e g 1 kS s for a 50 Hz sine wave If you have a lot of high frequency components it may be necessary to sample 100 times faster e g 5 kS s for the 50 Hz sine wave or even more If you display only the frequency domain FFT analysis a 2 5 times faster sampling would be...

Page 18: ...ghted in screen shot Illustration Measure mode shows the live measurement data in different widgets which are depending on the selected measurement screen In this case we see a simple recorder widget where data is presented in the time domain You can use the channel selector list to assign measurement channels to the widgets Each widget has different settings shows the settings of the currently se...

Page 19: ...es of the currently selected widget Differences are you have additional tool buttons there is a Signal overview window which will show you the whole data of one selected channel of the data file there are additional cursors Yellow and two white cursors Now you can use the cursors to analyse your data zoom in and out of the data click Offline math to add computations based on your data etc You can ...

Page 20: ...ick the Settings menu item Open settings dialogue The settings window will appear where all the currently connected devices will be seen If you add a device while this screen is open or if your device is not shown yet you can press the Refresh button to scan for devices When you select a device from the list you will see all the device details and settings in the right area Real measurement mode I...

Page 21: ...esoftX installation e g D DewesoftX System Firmwares Connect the Dewesoft instrument to the PC and run DewesoftX Go to settings under the Update tab Firmware update settings If the firmware package isn t selected select it by pressing the button and find the folder with the firmware file in it Select the device you want to upgrade and start the firmware upgrade by pressing the Upgrade button IOLIT...

Page 22: ...ses are seen under Active licenses tab If the license is recognized as none active it usually means that the wrong license was entered Active licenses tab All licenses regarding IOLITE will only work when the IOLITE system is connected to your PC and the device has been activated in the hardware setup 3 7 Troubleshooting If your IOLITE device is not found by DewesoftX If you did not restart Window...

Page 23: ...he Dewesoft EtherCAT devices here are some additional steps Check if there is an Ethercat DAQ Filter driver installed on your computer like shown on the picture below If the driver is installed make sure the checkbox is checked in front of the driver Ethernet properties If the driver is not installed it can be downloaded from our web page IOLITE V20 1 23 153 ...

Page 24: ...zed the Speed Duplex of the network card needs to be adjusted manually Go to network connections Right click on the connection where the EtherCAT devices are connected Go to configure advanced options find Speed Duplex change the value to 100 Mbps Full Duplex Ethernet advanced properties IOLITE V20 1 24 153 ...

Page 25: ... end system for industrial applications All in one solution for real time control and feedback monitoring Voltage Strain Stress Quarter Bridge Half Bridge Full Bridge Thermocouple Digital IO IEPE Charge Current LVDT RTD Resistance DSI Compatible TEDS Compatible EtherCAT IP40 10 C to 50 C IOLITE V20 1 25 153 ...

Page 26: ...OLITE R8 GREAT PRICE PERFORMANCE IOLITE offers a great price performance ratio and is suitable for test bed and industrial applications SOFTWARE INCLUDED WITH FREE LIFETIME UPGRADES Easy to use yet very robust in functionality award winning DewesoftX software is included The software comes with lifetime free upgrades and no hidden costs bringing you intuitive configuration smart sensors advanced s...

Page 27: ... module is a perfect choice for a general purpose voltage input data acquisition module due to high accuracy and high channel to channel and channel to ground isolation 16xLV Isolated 16 channel low voltage module 8xLA Isolated 8 channel low current module 8xTH isolated thermocouple amplifier 32xDI 32 channel digital input 32xDO 32 channel digital output with watchdog functionality 8xDI 4xDO 8 dig...

Page 28: ... really amazing is that IOLITE offers the operator to acquire and monitor the data in daily operation as well as while tuning the control systems Apart from monitoring the input channels on the data acquisition bus the system can also monitor the outputs from the controller Let s say we regulate the switch off valve by monitoring the pressure DewesoftX can show the pressure signal as well as the d...

Page 29: ...0 MB s Bus 1 connectors 2x Ethernet RJ45 2x Lemo 1T Bus 2 connectors 2x Ethernet RJ45 2x Ethernet RJ45 Minimum delay analog input to EtherCAT bus 70 µs 70 µs Minimum EtherCAT cycle time 100 µs 100 µs Power Power supply Dual redundant 12 48 V DC Dual redundant 12 48 V DC Power consumption 9 W to 11 W incl IOLITE GATE IOLITE GATE Max 1 9 W 8 W Max 9 W Environmental Operating Temperature 10 to 50 C 1...

Page 30: ...mple rate per device multiple chains possible Additional power injectors are necessary Data interface connection Ethernet RJ45 Single cable for data power and sync daisy chainable Power Power supply 12 V 48 V Power consumption 2 W see individual modules Environmental Operating Temperature 20 to 60 C Storage Temperature 20 to 60 C Humidity 95 no condensation IP rating IP20 Physical Dimensions 82 mm...

Page 31: ...s Standard IOLITE chassis is compatible and can be mounted in any 19 inch rack cabinet This is perfect for the test bed installations IOLITE height is 4U and can host up to 12 IOLITE modules It includes a cooling system with four fans on the back panel 4 3 1 1 IOLITE R12 Cabinet Mount Chassis Renders Mounting of IOLITE R12 in the 19 cabinet IOLITE R12 Cabinet Mount Chassis Front panel IOLITE V20 1...

Page 32: ...IOLITE TECHNICAL REFERENCE MANUAL Cooling system on the Back panel of IOLITE R12 4 3 1 2 IOLITE R12 Cabinet Mount Chassis Dimensions Technical Drawings of IOLITE R12 IOLITE V20 1 32 153 ...

Page 33: ...s and either PC other Dewesoft EtherCAT devices or 3rd party control masters It includes dual EtherCAT bus redundant power supply inputs and provides synchronization with Dewesoft USB devices IOLITE GATE is mounted in the first slot from left inside the IOLITE R12 19 inch rack cabinet chassis IOLITE GATE module IOLITE V20 1 33 153 ...

Page 34: ... data and Secondary bus BUS 2 for unbuffered data have IN and OUT connectors Two 2 pin LEMO 1B connectors are used for redundant power supply PWR IN Synchronization with Dewesoft USB data acquisition devices or connection to clock master is on IOLITE GATE enabled by connecting a synchronization cable to two SYNC inputs 4 pin LEMO 00 IOLITE GATE front IOLITE V20 1 34 153 ...

Page 35: ... the data from IOLITE with Dewesoft USB devices for the same measurement The signal that is transferred over sync cable makes sure that the measurement data of IOLITE and Dewesoft USB devices are perfectly synchronized to each other The other use of a sync connector is to connect directly to IOLITE a signal from the clock master Hint There is no distinction between the IN and OUT it does not matte...

Page 36: ...nector has two LEDs GREEN LED indicates that IOLITE is connected to another device Dewesoft EtherCAT device PC or 3rd party control master YELLOW LED is active only when the data transfer is active Connector used on the device is a standard Ethernet connector RJ45 Standard ethernet cable with standard connector can be used to connect IOLITE GATE with a PC EtherCAT connector pin out RJ 45 female Pi...

Page 37: ...e redundancy of the system it is recommended that the device is powered with two power supplies connected to different electrical fuses Then connect a standard ethernet cable to the IN connector of BUS 1 on IOLITE GATE Finally connect the other side of the ethernet cable to the LAN port of PC Connection of IOLITE R12 standalone device to PC List of required cables Function Dewesoft order code Powe...

Page 38: ...the USB port on PC In order to have synchronized data between IOLITE and DEWE 43A connect SYNC cable e g L00B4m L00B4m 0 2m to the SYNC connector on IOLITE GATE and the other side of cable to the SYNC connector on DEWE 43A Connection of IOLITE R12 and DEWE 43A device List of required cables Function Dewesoft order code Power supply IOLITE R12 PS 120 L1B2f default DEWE 43A PS 60W 12V 5A L1B2f defau...

Page 39: ...le to the IOLITE single channel device You need to connect the PS with the cable to the IOLITE POWER INJECTOR Use the RJ45 to RJ45 cable again to connect the data line to IOLITE multi channel device The IOLITE multi channel device will need an additional Power supply Connection of IOLITE R12 IOLITE single channel and IOLITE multi channel Function Dewesoft order code Power supply IOLITE R12 PS 120 ...

Page 40: ...LITE is also available in standalone aluminium chassis compatible with Sirius data acquisition instruments The chassis provides 8 slots for IOLITE input and output slices to be installed IOLITE R8 includes EtherCAT gateway and cooling system 4 3 2 1 IOLITE R8 Boxed Chassis Renders IOLITE R8 Front panel IOLITE V20 1 40 153 ...

Page 41: ...IOLITE TECHNICAL REFERENCE MANUAL IOLITE R8 Back panel IOLITE V20 1 41 153 ...

Page 42: ...IOLITE TECHNICAL REFERENCE MANUAL 4 3 2 2 IOLITE R8 Boxed Chassis Dimensions Technical Drawings of IOLITE R8 IOLITE V20 1 42 153 ...

Page 43: ...n LEMO 1B connectors are used for redundant power supply PWR IN Above the PWR IN connector is a GND socket for grounding the IOLITE R8 Synchronization with Dewesoft USB data acquisition devices or connection to clock master is on IOLITE R8 enabled by connecting a synchronization cable to two SYNC inputs 4 pin LEMO 00 4 3 2 3 1 IOLITE R8 Boxed Chassis Power in Pinout Power in connector pin out 2 pi...

Page 44: ...ices are perfectly synchronized to each other The other use of a sync connector is to connect directly to IOLITE a signal from the clock master Hint There is no distinction between the IN and OUT it does not matter which connector you use When IRIG synchronisation is used the IRIG signal is on pins 1 2 Sync connector pin out 4 pin LEMO female Pin Name Description 1 CLK Clock 2 TRIG Trigger 3 RES P...

Page 45: ...n LEMO 1B male connector EtherCAT connector pin out 8 pin LEMO male Pin Name Description 1 TX_P Transmission 2 TX_N Transmission 3 RX_P Reception 4 RX_N Reception 5 VCC Power IN 6 VCC Power IN 7 GND Ground 8 GND Ground BUS 1 IN connector on the device EEJ 1B 308 CLD Mating connector for the cable FGJ 1T 308 CLL 1433 IOLITE V20 1 45 153 ...

Page 46: ...ector enables power supply for external Dewesoft EtherCAT devices EtherCAT connector pin out 8 pin LEMO female Pin Name Description 1 TX_P Transmission 2 TX_N Transmission 3 RX_P Reception 4 RX_N Reception 5 VCC Power OUT 6 VCC Power OUT 7 GND Ground 8 GND Ground BUS 1 OUT connector on the device EEG 1B 308 CLN Mating connector for the cable FGG 1T 308 CLA 1433 IOLITE V20 1 46 153 ...

Page 47: ...hat IOLITE is connected to another device YELLOW LED is active only when the data transfer is active Connector used on the device is a standard ethernet connector RJ45 Standard ethernet cable with standard connector can be used to connect IOLITE GATE with a PC EtherCAT connector pin out RJ 45 female Pin Name Description 1 TX_P Transmission 2 TX_N Transmission 3 RX_P Reception 4 5 6 RX_N Reception ...

Page 48: ... of the system it is recommended that the device is powered with two power supplies connected to different electrical fuses Then connect L1T8f RJ45 1M cable LEMO side to IN connector of BUS 1 on the IOLITE R8 back panel Finally connect the other side of the L1T8f RJ45 1M cable RJ45 side to the LAN port of the PC Connection of IOLITE R8 standalone device to PC List of required cables Function Dewes...

Page 49: ...8f 1M and connect it to OUT connector on BUS 1 of IOLITE R8 on one side and to IN connector of KRYPTON device on the other side Connection of IOLITE R8 and KRYPTON device List of required cables Function Dewesoft order code Power supply PS 120 L1B2f default EtherCAT IOLITE to PC L1T8f RJ45 1M default L1T8f RJ45 3M L1T8f RJ45 5M IOLITE to KRYPTON L1T8m L1T8f 02M L1T8m L1T8f 0 4M L1T8m L1T8f 1M L1T8...

Page 50: ... power supply daisy chain cable e g L1B2m L1B2f 0 4m to enable power supply for IOLITE R8 Then connect L1T8f RJ45 1M cable LEMO side to the IN connector of BUS 1 on the IOLITE R8 back panel Finally connect the other side of the L1T8f RJ45 1M cable RJ45 side to the LAN port of PC In order to have synchronized data between IOLITE and Sirius connect SYNC cable e g L00B4m L00B4m 0 2m to the SYNC conne...

Page 51: ...L00B4m L00B4m 0 5m L00B4m L00B4m 3m 4 3 2 7 IOLITE R8 Boxed Chassis Connection of IOLITE multi and single channel device Connect power supply cable to IOLITE R8 PS 120W L1B2f Then connect L1T8f RJ45 1M cable LEMO side to IN connector of BUS 1 on IOLITE R8 back panel Use the L1T8m RJ 45 cable to connect the IOLITE single channel device An additional power cable is not needed as the device can power...

Page 52: ...NUAL Function Dewesoft order code Power supply IOLITE R8 PS 120 L1B2f default IOLITE multichannel EtherNET IOLITE R8 to IOLITE single channel RJ 45 RJ 45 IOLITE single channel to IOLITE multi channel RJ 45 RJ 45 IOLITE V20 1 52 153 ...

Page 53: ...ndard industrial DIN rail mounts IOLITEI DAQ devices use RJ45 connectors which allow easy connection of modules with standard low cost Ethernet EtherCAT cables Important For the power supply we have two TBLOCK connectors so the devices can be daisy chained with each other 4 3 2 8 IOLITE Multi channel Renders IOLITE multi channel device Old render the new IOLITEi has two power connectors IOLITE V20...

Page 54: ...CAL REFERENCE MANUAL 4 3 2 9 IOLITE Multi channel Dimension Old dimensions the new IOLITEi has two power connectors 4 3 2 10 IOLITE Multi channel Connectors 4 3 2 10 1 IOLITE Multi channel PWR IN IOLITE V20 1 54 153 ...

Page 55: ... BX 4 3 2 10 1 IOLITE Multi channel PWR OUT Pin Name Description 1 Supply 2 Ground Power in connector pin out 2 pin male Connector on the device SL SMT 5 08HC 02 90F 3 2SN BK BX Mating Connectors for the cable BLF 5 08HC 02 180 SN BK BX BLZP 5 08HC 02 180 SN BK BX Pin Name Description 1 Supply 2 Ground 4 3 2 10 2 EtherNET in Connector used on the device is a standard Ethernet connector RJ45 IOLITE...

Page 56: ...X_P Reception 4 5 6 RX_N Reception 7 8 4 3 2 10 3 EtherNET out Connector used on the device is a standard Ethernet connector RJ45 Standard ethernet cable with standard connector can be used to connect IOLITE Multi channel device with an additional IOLITE Multi channel device EtherCAT connector pin out RJ 45 female Pin Name Description 1 TX_P Transmission 2 TX_N Transmission 3 RX_P Reception 4 5 6 ...

Page 57: ... for easy mounting with screws or any other method Multiple IOLITE modules can be daisy chained together with a single cost effective Ethernet EtherCAT cable with RJ45 connectors Devices can span up to 100m apart Single EtherCAT cable is enough for power data and synchronization between devices 4 3 3 1 IOLITE Single channel Renders IOLITE single channel device IOLITE V20 1 57 153 ...

Page 58: ...nector used on the device is a standard Ethernet connector RJ45 Standard ethernet cable with standard connector can be used to connect IOLITE Single channel with a PC EtherCAT connector pin out RJ 45 female Pin Name Description 1 TX_P Transmission 2 TX_N Transmission 3 RX_P Reception 4 DC PoE 5 DC PoE 6 RX_N Reception 7 DC PoE 8 DC PoE IOLITE V20 1 58 153 ...

Page 59: ...thernet connector RJ45 Standard ethernet cable with standard connector can be used to connect IOLITE Single channel with a PC EtherCAT connector pin out RJ 45 female Pin Name Description 1 TX_P Transmission 2 TX_N Transmission 3 RX_P Reception 4 DC PoE 5 DC PoE 6 RX_N Reception 7 DC PoE 8 DC PoE IOLITE V20 1 59 153 ...

Page 60: ...DC Sensor excitation 0 12 V bipolar 0 24 V unipolar max 0 4 W ch 1 V 2 V 5 V Bridge connection Full 350 Ω 120 Ω 3 wire Full 350 Ω 120 Ω 3 wire Programmable shunt 100 kΩ 100 kΩ IEPE input DSI ACC Current 20 mA internal shunt DSI 5A 20 mA 2 mA Temperature PTx DSI RTD PT100 200 500 1000 2000 Thermocouple DSI TH K J T R S N E C U B Resistance 1 kΩ 10 kΩ Potentiometer LVDT DSI LVDT Charge DSI CHG TEDS ...

Page 61: ...e ranges 1 V 100 mV open collector TTL Low 0 8 V High 2 V 10 V Input coupling DC Sensor excitation 5 V 12 V Bridge connection Programmable shunt IEPE input Current Temperature PTx PT100 200 500 1000 2000 Thermocouple Resistance 1 kΩ 10 kΩ Potentiometer LVDT Charge TEDS Isolation voltage 1000 V 1000 V 1000 V 1000 V Power consumption per module Typ 2 1 W Max 2 7 W Typ 1 2 W Max 1 9 W Typ 1 2 W Max 2...

Page 62: ...X Alias Rejection 100 dB all sample rates 100 dB all sample rates X X X Delay Through ADC 37 fs 37 fs X X X Oversampling 32 32 X X X Voltage ranges 10 V 5 V 1 V 200 mV 50 V 10 V 1 V 100 mV Digital Low 1 V High 2 V X 10 V Isolation 125 Vrms Isolation CH GND 125 Vrms Isolation CH GND CH CH GND GND CH GND X Power supply 12 48V 12 48V 12 48V 12 48V 12 48V Power consumption 2W 2 5W 2 5W 2 5W 2W Operati...

Page 63: ...des a power out option where unregulated power supply voltage is brought to the 2 pin PWR OUT connector Digital output modules also offer watchdog functionality They are a perfect choice for control applications Hint IOLITEi 4xDO offers a software option for PWM output Hint Find out more about Watchdog feature in Watchdog User Manual https download dewesoft com list manuals brochures software manu...

Page 64: ...IOLITE TECHNICAL REFERENCE MANUAL 5 1 2 IOLITEi 32xDO Module IOLITEi 32xDO module IOLITE V20 1 64 153 ...

Page 65: ...IOLITE TECHNICAL REFERENCE MANUAL 5 1 3 IOLITEi 8xDI 4xDO Module IOLITEi 8xDI 4xDO module IOLITE V20 1 65 153 ...

Page 66: ...vailable on the front connector EtherCAT interface signal and power over the same cable IOLITEi 4xDO module 5 1 5 IOLITEi 4xDI Robust isolated digital inputs are suitable for reading data off digital sensors as well as for demanding test automation tasks Three power supply voltages V 12V and device voltage supply level available on the front connector EtherCAT interface signal and power over the s...

Page 67: ...80 Power supply 12 48 V DC Power out max 2 A unprotected Power consumption Typ 1 2 W Max 1 9 W Weight 220 g Slice Dimensions 128 4 x 115 4 x 30 1 mm IOLITEi 32xDO Digital Output Isolated Output Channels 32 Compatibility Solid state relay Maximum sink current 0 5 A Maximum switching voltage 50 V Maximum update rate depending on EtherCAT master Isolation voltage peak 1000 V channel to ground no chan...

Page 68: ... to channel Digital Output Isolated Output Channels 4 Compatibility Solid state relay Maximum sink current 0 5 A Maximum switching voltage 50 V Maximum update rate depending on EtherCAT master Isolation voltage peak 1000 V channel to ground no channel to channel isolation Additional Specifications Input connectors Terminal block 3 x 2 pole 2 x 12 pole 1 x 8 pole OMNIMATE SL 2 50 BLF 2 50 180 Power...

Page 69: ...or internal PWM 100 kHz Isolation Galvanic isolation CH GND Non Isolated Sensor Power Supply Output Voltage 5 V 5 V 10 300 mA max Max combined load on 5 V and 12 V pins 1 5 W reduced by the load already present on Vin pin Output Voltage 12 V 12 V 10 100 mA max Max combined load on 5 V and 12 V pins 1 5 W reduced by the load already present on Vin pin Output Voltage Vecat EtherCAT Bus Supply Voltag...

Page 70: ...t 30 V UIN 6 mA typ Propagation delay 1 μs Max sampling rate 40 kS sec Overvoltage protection 30 V Continuous 65 V peak Isolation Galvanic isolation CH GND Non Isolated Sensor Power Supply Output Voltage 5 V 5 V 10 300 mA max Output Voltage 12 V 12 V 10 100 mA max Output Voltage Vecat EtherCAT Bus Supply Voltage 200 mA max Power Power consumption 2 5 W Environmental IP rating IP20 Physical Dimensi...

Page 71: ... connectors with 2 50 mm pitch for digital input output 8 pins on a 9 pin connector bank are used for digital inputs and pin 9 for common GND Additionally there is a 2 pin terminal block connector with a 2 50 mm pitch for PWR OUT function IOLITEi 32xDI front IOLITEi 32xDO front IOLITEi 8xDI 4xDO front IOLITE V20 1 71 153 ...

Page 72: ...ital Input Pinout Digital in connector pin out terminal block male Pin Name Description 1 DI 1 Digital input 1 2 DI 2 Digital input 2 3 DI 3 Digital input 3 4 DI 4 Digital input 4 5 DI 5 Digital input 5 6 DI 6 Digital input 6 7 DI 7 Digital input 7 8 DI 8 Digital input 8 9 COM Common ground DI connector on the device OMNIMATE Signal SL 2 50 09 90G Mating connector for the cable OMNIMATE Signal BLF...

Page 73: ... DO 1 Digital output 1 2 DO 2 Digital output 2 3 DO 3 Digital output 3 4 DO 4 Digital output 4 5 DO 5 Digital output 5 6 DO 6 Digital output 6 7 DO 7 Digital output 7 8 DO 8 Digital output 8 9 COM Common ground DO connector on the device OMNIMATE Signal SL 2 50 09 90G Mating connector for the cable OMNIMATE Signal BLF 2 50 09 180 IOLITE V20 1 73 153 ...

Page 74: ...e device OMNIMATE Signal SL 2 50 02 90G Mating connector for the cable OMNIMATE Signal BLF 2 50 02 180 5 1 7 5 IOLITEi 8xDI 4xDO Power In Pinout Power in connector pin out terminal block male Pin Name Description 1 PWR IN DI Input voltage 2 PWR IN DI Input ground PWR OUT connector on the device OMNIMATE Signal SL 2 50 02 90G Mating connector for the cable OMNIMATE Signal BLF 2 50 02 180 IOLITE V20...

Page 75: ...9 Input ground 10 Input voltage 11 DI 4 Digital input 4 12 Input ground DO connector on the device OMNIMATE Signal SL 2 50 09 90G Mating connector for the cable OMNIMATE Signal BLF 2 50 09 180 5 1 7 7 IOLITEi 8xDI 4xDO Power In Pinout Power in connector pin out terminal block male Pin Name Description 1 PWR IN DO Input voltage 2 PWR IN DO Output ground PWR OUT connector on the device OMNIMATE Sign...

Page 76: ... male Pin Name Description 1 DO 1 Digital output 1 2 Output ground 3 DO 2 Digital output 2 4 Output ground 5 DO 3 Digital output 3 6 Output ground 7 DO 4 Digital output 4 8 Output ground DO connector on the device OMNIMATE Signal SL 2 50 09 90G Mating connector for the cable OMNIMATE Signal BLF 2 50 09 180 IOLITE V20 1 76 153 ...

Page 77: ...4 Digital input CH4 DO4 Digital output CH4 5 NC Vext External voltage 6 DI1 Digital input CH1 GNDi Isolated ground 7 DI2 Digital input CH2 GNDi Isolated ground 8 DI3 Digital input CH3 GNDi Isolated ground 9 DI4 Digital input CH4 GNDi Isolated ground 10 NC NC 11 5V 300mA 5 V supply max 300 mA 5V 300mA 5 V supply max 300 mA 12 12V 130mA 12 V supply max 130 mA 12V 130mA 12 V supply max 130 mA 13 GND ...

Page 78: ...he perfect choice for general purpose low voltage input data acquisition due to its high accuracy and high isolation The 8 channel module has channel to channel isolation and comes with either BNC or terminal block connectors and a range of either 10 or 100 V On the other hand the 16 channel version only comes with channel to ground isolation in the form of terminal block connectors but a higher r...

Page 79: ...IOLITE TECHNICAL REFERENCE MANUAL 5 2 2 IOLITE 16xLV IOLITE 16xLV TBLOCK modules have TBLOCK connectors for analog input IOLITE 16xLV TBLOCK module IOLITE V20 1 79 153 ...

Page 80: ...B Typical CMR 400 Hz 1 kHz 98 dB 90 dB 83 dB 75 dB Gain Drift Typical 10 ppm K Max 40 ppm K Offset Drift Typical 2 ppm of range K Max 10 ppm of range K Gain Linearity 0 02 Input Coupling DC Input Impedance 1 MΩ Overvoltage Protection In to In 200 V continuous 350 Vpeak 100 ms Analog input performance Bandwidth 3 dB 0 49 fs Alias free Bandwidth DC to 0 453 fs Alias Rejection 100 dB all sample rates...

Page 81: ...z 1 kHz 88 dB 87 dB 82 dB 80 dB Crosstalk 1 kHz 118 dB 120 dB Gain Drift Typical 10 ppm K Max 40 ppm K Offset Drift Typical 2 ppm of range K Max 5 ppm of range K Gain Linearity 0 01 Input Coupling DC Input Impedance 1 MΩ 500 kΩ Overvoltage Protection In to In 200 V continuous 350 Vpeak 100 ms Analog input performance Bandwidth 3 dB 0 433 fs Alias free Bandwidth 0 499 fs Alias Rejection 105 dB all ...

Page 82: ...LITE TECHNICAL REFERENCE MANUAL 5 2 4 LV Connectors 5 2 4 1 IOLITEi 8xLV BNC Connector IOLITE LV module has 8 BNC connectors for analog input IOLITEi 8xLV front IOLITEi 8xLV 10V front IOLITE V20 1 82 153 ...

Page 83: ... REFERENCE MANUAL 5 2 4 2 IOLITEi 8xLV BNC Connector Pin out LV connector pin out BNC Pin Name Description 1 IN Analog input 2 GND Ground 5 2 4 3 LV BNC Connector Wiring diagram 5 2 4 3 1 LV Voltage IOLITE V20 1 83 153 ...

Page 84: ...ENCE MANUAL 5 2 4 4 IOLITEi 8xLV TBLOCK Connector IOLITEi 8xLV TBLOCK and IOLITEi 8xLV 10V TBLOCK modules have 8 TBLOCK connectors for analog input IOLITEi 8xLV TBLOCK front IOLITEi 8xLV 10V TBLOCK front IOLITE V20 1 84 153 ...

Page 85: ...pin out TBLOCK male Pin Name Description 1 IN Analog input 2 IN Analog input Connector on the device OMNIMATE Signal SL 2 50 02 180G 3 2SN BK BX Mating connector for the cable OMNIMATE Signal BLF 2 50 02 180 5 2 4 6 8xLV TBLOCK Connector Wiring diagram 5 2 4 6 1 8xLV Voltage IOLITE V20 1 85 153 ...

Page 86: ...or analog input IOLITEi 16xLV TBLOCK front 5 2 4 8 IOLITE 16xLV TBLOCK Power Connector Pinout LV connector pin out TBLOCK male Pin Name Description 1 IN Analog input 2 IN Analog input Connector on the device OMNIMATE Signal SL 2 50 02 90G Mating connector for the cable OMNIMATE Signal BLF 2 50 02 180 IOLITE V20 1 86 153 ...

Page 87: ...tion 1 AI 1 Analog input 1 2 AI 1 Input ground 1 3 AI 2 Analog input 2 4 AI 2 Input ground 2 5 AI 3 Analog input 3 6 AI 3 Input ground 3 7 AI 4 Analog input 4 8 AI 4 Input ground 4 9 GND Common ground AI connector on the device OMNIMATE Signal SL 2 50 09 90G Mating connector for the cable OMNIMATE Signal BLF 2 50 09 180 IOLITE V20 1 87 153 ...

Page 88: ...IOLITE TECHNICAL REFERENCE MANUAL 5 2 4 10 16xLV TBLOCK Connector Wiring diagram 5 2 4 10 1 16xLV Voltage IOLITE V20 1 88 153 ...

Page 89: ...hannel low current measurement module It is a perfect device for data acquisition in control applications requiring an input current range of 20 mA It features channel to channel isolation and comes with either BNC or terminal block connectors IOLITEi 8xLA modules IOLITE V20 1 89 153 ...

Page 90: ...5 ppm of range K Max 15 ppm of range K Gain Linearity 0 05 Input Coupling DC Input Impedance 50 Ω Overvoltage Protection In to In 20 V continuous 30 Vpeak 100 ms Overcurrent Protection In to In 70 mA continuous Analog input performance Bandwidth 3 dB 0 49 fs Alias free Bandwidth DC to 0 453 fs Alias Rejection 100 dB all sample rates Delay Through ADC 37 fs Oversampling 32 Additional Specifications...

Page 91: ...TE TECHNICAL REFERENCE MANUAL 5 3 2 LA BNC Connector IOLITE 8xLA BNC module 5 3 2 1 8xLA BNC Connector Pinout LV connector pin out BNC Pin Name Description 1 IN Analog input 2 GND Ground IOLITE V20 1 91 153 ...

Page 92: ...IOLITE TECHNICAL REFERENCE MANUAL 5 3 2 2 8xLA BNC Connector Wiring diagram 5 3 2 2 1 8xLA Current IOLITE V20 1 92 153 ...

Page 93: ...ule 5 3 3 1 8xLA TBLOCK Connector Pinout LA connector pin out TBLOCK male Pin Name Description 1 IN Analog input 2 IN Analog input Connector on the device OMNIMATE Signal SL 2 50 02 180G 3 2SN BK BX Mating connector for the cable OMNIMATE Signal BLF 2 50 02 180 IOLITE V20 1 93 153 ...

Page 94: ...IOLITE TECHNICAL REFERENCE MANUAL 5 3 3 2 8xLA TBLOCK Connector Wiring diagram 5 3 3 2 1 8xLA Current IOLITE V20 1 94 153 ...

Page 95: ...IOLITEi RTD module with 6 pin LEMO 0B input connectors is used for measurements with universal platinum thermometer probes thermistors as well as for resistance and voltage measurements IOLITEi 8xRTD module has 8 isolated measurement channels IOLITEi 8xRTD module IOLITE V20 1 95 153 ...

Page 96: ...μV K max 0 2 μV K Gain Linearity 0 01 Input Coupling DC Input Impedance 1 MΩ Temperature PT500 PT1000 PT2000 PT100 PT200 Measurement range 200 C to 850 C Accuracy 0 05 of reading 0 2 C Temperature Drift typ 5 ppm K max 12 ppm K 0 003 C K Input Connection 3 wire or 4 wire Resolution 0 001 C Resistance 0 10 kΩ 0 1 kΩ Accuracy 0 02 of reading 0 01 of range Input Connection 3 wire or 4 wire Additional...

Page 97: ...000 PT100 Excitation current 0 4 mA or 0 4 mA 2 mA or 2 mA Excitation type DC or DC squared from 5Hz to 50Hz Measurement range 200 C to 850 C Accuracy 0 05 of reading 0 2 C Temperature Drift typ 5 ppm K max 12 ppm K 0 003 C K Input Connection 2 wire 3 wire or 4 wire Resolution 0 001 C Resistance 0 10 kΩ 0 1 kΩ Excitation current 0 4 mA or 0 4 mA 2 mA or 2 mA Excitation type DC or DC squared from 5...

Page 98: ...IOLITE TECHNICAL REFERENCE MANUAL 5 4 2 RTD LEMO L0B6f Connector IOLITEi 8xRTD and IOLITEi 8xRTDp module have eight 6 pin LEMO 0B female connectors IOLITEi 8xRTD front IOLITE V20 1 98 153 ...

Page 99: ... female Pin Name Description 1 In Input 2 In Input 3 NC Do not connect 4 Exc Excitation 5 Exc Excitation 6 NC Do not connect RTD connector on the device EEA 0B 306 CLN Mating connector for the cable FGA 0B 306 CLAD21Z 5 4 2 2 RTD LEMO L0B6f Connector Wiring diagram 5 4 2 2 1 RTD Voltage IOLITE V20 1 99 153 ...

Page 100: ...IOLITE TECHNICAL REFERENCE MANUAL 5 4 2 2 2 RTD Resistance 3 wire 4 wire 5 4 2 2 3 RTD Temperature 3 wire 4 wire IOLITE V20 1 100 153 ...

Page 101: ... TECHNICAL REFERENCE MANUAL 5 4 3 RTD TBLOCK Terminal block connector IOLITEi 8xRTD TBLOCK module has 8 terminal block Weidmueller SL 2 50 04 female connectors IOLITEi 8xRTD TBLOCK front IOLITE V20 1 101 153 ...

Page 102: ...TECHNICAL REFERENCE MANUAL 5 4 3 1 RTD TBLOCK Terminal block connector Pinout RTD connector pin out TBLOCK male Pin Name Description 1 In Input 2 In Input 3 Exc Excitation 4 Exc Excitation IOLITE V20 1 102 153 ...

Page 103: ...ull Half Quarter bridge input with DSUB 9 connector Compatible with DSI adapters for IEPE CHG 200 V RTD TH measurements IOLITE 6xSTG module 5 5 2 IOLITEi 1xSTG IOLITEi 1xSTG is a single channel strain gauge amplifier with internal quarter half and full bridge configurations Low noise voltage and current source excitation are available with freely settable levels Input ranges span from 50V to 100mV...

Page 104: ...ding 0 02 of range 0 1 mV Typical Dynamic Range 10 kS 100 dB 110 dB 130 dB 145 dB Typical Noise floor 10 kS 103 dB 97 dB 103 dB 94 dB Typical CMR 400 Hz 1 kHz 71 dB 66 dB 72 dB 66 dB 96 dB 88 dB 96 dB 87 dB Gain Drift Typical 10 ppm K max 40 ppm K Offset Drift Typical 0 3 μV K 5 ppm of range K max 2 μV K 10 ppm of range K Gain Linearity 0 02 Input Coupling DC AC 1Hz Input Impedance 1 MΩ 1 MΩ 20 MΩ...

Page 105: ...0 mA 0 5 5 μA 10 mA Bridge measurement Bridge Connection Types full bridge strain bridge strain bridge strain 3 wire Ranges 2 1000 mV V free programmable Internal Bridge Completion bridge and bridge 120 and 350 Ω Bridge Completion Accuracy 0 05 TCR 5 ppm K others on request Internal Shunt Resistor 100 kΩ others on request Shunt Resistor Accuracy 0 05 TCR 10 ppm K others on request Input Short Sens...

Page 106: ... Overvoltage Protection Range 10 V 200 V Range 10 V 50 V Isolation 125 Vrms channel to ground isolation TEDS support Standard DSI adapters Analog input Current Current ranges 2 mA 20 mA Input Accuracy 0 03 of reading 0 02 of range 2 1 μA Internal Shunt resistor 50 Ω Analog input performance Bandwidth 3 dB 0 49 fs Alias free Bandwidth DC to 0 453 fs Alias Rejection 100 dB all sample rates Delay Thr...

Page 107: ...ernal Shunt Resistor 100 kΩ others on request Shunt Resistor Accuracy 0 1 TCR 10 ppm K others on request Input Short Sensor Offset Adjust Software selectable Power Power consumption 2 5 W Environmental IP rating IP20 Physical Dimensions 71 x 62 x 28 mm Weight 130 g Rev 1593518446 IOLITE V20 1 107 153 ...

Page 108: ... female connectors for voltage or strain measurement IOLITE 6xSTG front 5 5 5 1 DSUB 9 Connector Pinout STG connector pin out DSUB 9 female Pin Name Description 1 Exc Excitation 2 In Input 3 Sns Sense 4 GND Ground 5 R Bridge Shunt 6 Sns Sense 7 In Input 8 Exc Excitation 9 TEDS TEDS IOLITE V20 1 108 153 ...

Page 109: ...ANUAL 5 5 5 2 STG DSUB 9 Connector Wiring diagram 5 5 5 2 1 STG Voltage Single ended Differential Use only when sensor Output and Output are referenced to Gnd Gnd must be connected 5 5 5 2 2 STG Potentiometer IOLITE V20 1 109 153 ...

Page 110: ...IOLITE TECHNICAL REFERENCE MANUAL 5 5 5 2 3 STG Bridge Full bridge Half bridge Quarter bridge IOLITE V20 1 110 153 ...

Page 111: ...IOLITE TECHNICAL REFERENCE MANUAL 5 5 5 2 4 STG Current External direct shunt External loop powered shunt Internal shunt IOLITE V20 1 111 153 ...

Page 112: ...IOLITE TECHNICAL REFERENCE MANUAL 5 5 5 2 5 STG Resistance IOLITE V20 1 112 153 ...

Page 113: ...odule STGS is a dedicated module for strain measurement with a new ADC 24 bit delta sigma with anti aliasing filter The module can be found in the following options 6xSTGS as a slot slice 6xSTGS as a standalone module IOLITE 8 STGS module IOLITE V20 1 113 153 ...

Page 114: ...K Gain Linearity 0 02 Input Coupling DC Analog input performance Bandwidth 3 dB 0 433 fs Sinc5 filter 0 204 fs Alias free Bandwidth DC to 0 499 fs Alias Rejection 105 dB all sample rates Delay Through ADC 34 fs Sinc5 filter 3 fs Oversampling 128 Excitation Voltage Excitation Voltage 1 V 2 V 5 V Current Limit 42 mA Protection Continuous short to ground Bridge measurement Bridge Connection Types ful...

Page 115: ...NCE MANUAL TEDS support Available for Terminal block D SUB9 Micro D Power supply 9 48 V DC Power Consumption Typ 2 7 W Max 5 1 W 120 Ω 5 V load 5 6 2 STGS Connectors 5 6 2 1 STGS D SUB37 Connector Pinout IOLITE V20 1 115 153 ...

Page 116: ...IOLITE TECHNICAL REFERENCE MANUAL 5 6 2 2 STGS Wiring diagram 5 6 2 2 1 STGS D SUB37 Voltage Single ended Differential 5 6 2 2 2 STGS D SUB37 Potentiometer IOLITE V20 1 116 153 ...

Page 117: ... TH Thermocouple Module IOLITE TH modules are isolated DAQ devices for temperature measurements using thermocouples Isolated thermocouple modules can acquire data from any kind of thermocouple K J T R S N E C B It offers sensor break detection in software as well as using LED indicators IOLITE V20 1 117 153 ...

Page 118: ...2 of reading 100 μV 0 02 of reading 10 μV Typical Noise floor 10 100 S sec 114 dB 105 dB 109 dB 100 dB Gain Drift Typical 4 ppm K max 10 ppm K Offset Drift Typical 0 05 μV K max 0 2 μV K Gain Linearity 0 01 Input Coupling DC Input Impedance 100 MΩ Thermocouple TC Types K J T R S N E C B Accuracy 0 02 of reading 0 5 C 10 μV Resolution 0 001 C Sampling rates 10 20 40 80 100 S sec Typical Noise 0 007...

Page 119: ...ifications Input connectors Mini Thermocouple connector copper Isolation voltage 1000 Vpeak channel to ground channel to channel Power supply 12 48 V DC Power consumption 3 2 W Weight 230 g Slice Dimensions 128 4 x 115 4 x 30 1 mm IOLITE V20 1 119 153 ...

Page 120: ...Connector IOLITEi 8xTH module has 8 miniature thermocouple connectors for temperature measurement IOLITEi 8xTH front 5 7 2 1 TH Miniature Thermocouple Connector Pinout TH connector pin out Mini TC female Pin Name Description 1 In Input 2 In Input IOLITE V20 1 120 153 ...

Page 121: ...LITE TECHNICAL REFERENCE MANUAL 5 7 2 2 TH Miniature Thermocouple Connector Wiring diagram 5 7 2 2 1 TH Voltage 5 7 2 2 2 TH Temperature T type thermocouple S type R type thermocouple IOLITE V20 1 121 153 ...

Page 122: ...IOLITE TECHNICAL REFERENCE MANUAL N type thermocouple K type thermocouple J type thermocouple E type thermocouple B type thermocouple C type thermocouple IOLITE V20 1 122 153 ...

Page 123: ...er Module IOLITE CNT has 4 channels each capable of 3x digital inputs 1x event counter encoder period pulse width duty cycle and precise frequency and angle measurement using patented SUPERCOUNTER technology IOLITE 4xCNT Module IOLITE V20 1 123 153 ...

Page 124: ...atibility TTL Low 0 8 V High 2 V Input impedance 100 kΩ pull up to 3 3 V Input Protection 25 V continuous Sensor supply 5 V 100 mA 12 V 50 mA Counter modes counting waveform timing encoder gear tooth sensor Additional Specifications Input connector 7 pin LEMO 1B series EEG 1B 307 CLNY Preliminary Terminal block OMNIMATE Signal SL Series SL 2 50 09 90G Power supply 12 48 V DC Slice Dimensions 128 4...

Page 125: ...IOLITE TECHNICAL REFERENCE MANUAL 5 8 2 CNT LEMO L1B7f Connector IOLITE 4xCNT module has four 7 pin LEMO connectors for digital counter and encoder inputs IOLITE 4xCNT Front IOLITE V20 1 125 153 ...

Page 126: ...0 A 2 IN1 B Digital input 1 B 3 IN2 Z Digital input 2 Z 4 GND Ground 5 5V 5 V supply 6 12V 12 V supply 7 GND Ground Connector on the module EGG 1B 307 CLL Mating cable connector FGG 1B 307 CLAD52 5 9 AO Analog output module The IOLITE AO module comes in the following options 16xAO slot slice 16xAO single slice 1xAO single channel device IOLITE V20 1 126 153 ...

Page 127: ...xAO IOLITE 16xAO Module 5 9 2 IOLITE 1xAO Low latency high precision analog output with excellent dynamic performance Under 100 microseconds of etherCAT to analog delay possible on a real time EtherCAT controller IOLITE 1xAO Front IOLITE V20 1 127 153 ...

Page 128: ...ling time 0 05 of set value 140 µs Max slew rate 0 20 V µs Max capacitive load 2 overshoot 10 nF Output protection Short circuit protected Current limit 20 mA per channel 160 mA per module Isolation Channel to ground Additional Specifications Output connectors Terminal block 2 pole 4 x 9 pole OMNIMATE SL 2 50 BLF 2 50 180 Power supply 12 48 V DC Power out max 2 A Power consumption Typ 4 3 W Max 7 ...

Page 129: ...9 V THD 90 dB Output impedance 0 45 Ω DC Maximum output current 20 mA Settling time 0 05 of set value 30 μs 1000 Ω load 10 V to 10 V step Max slew rate 2 5 V μs 1000 Ω load Max capacitive load 2 overshoot 10 nF Maximum load 500 Ω Output protection Short circuit protected Isolation X Power Power consumption 2 W Environmental IP rating IP20 Physical Dimensions 82 x 62 x 28 mm Weight 130 g 1 Only asy...

Page 130: ...xAO Front 5 9 4 1 IOLITE 16xAO TBLOCK Power Connector Pinout LV connector pin out TBLOCK male Pin Name Description 1 IN Analog input 2 IN Analog input Connector on the device OMNIMATE Signal SL 2 50 02 90G Mating connector for the cable OMNIMATE Signal BLF 2 50 02 180 IOLITE V20 1 130 153 ...

Page 131: ... AO 2 Analog out 2 4 iGND Ground 5 AO 3 Analog out 3 6 iGND Ground 7 AO 4 Analog out 4 8 iGND Ground 9 iGND Ground Connector on the device OMNIMATE Signal SL 2 50 09 90G 3 2SN BK BX Mating connector for the cable OMNIMATE Signal BLF 2 50 09 180 5 9 4 3 IOLITE 1xAO BNC Connector Pinout AO connector pin out BNC Pin Name Description 1 Out Output 2 Out Output IOLITE V20 1 131 153 ...

Page 132: ...10 V 5 V 1 V 200 mV Typ Input Accuracy 0 03 of reading 0 02 of range 0 1 mV Typ SNR 10 kS sec 1 dBFS sine wave 1 kHz 90 dB 90 dB 89 dB 88 dB Type SFDR 10 kS sec 1 dBFS sine wave 1 kHz 113 dB 110 dB 109 dB 106 dB Typ Noise floor 10 kS sec 100 dB 99 dB 99 dB 98 dB Typical CMR 400 Hz 1 kHz 130 dB 120 dB 122 dB 119 dB 104 dB 97 dB 90 dB 84 dB Gain Drift typ 10 ppm K max 40 ppm K Offset Drift typ 0 3 μ...

Page 133: ... Oversampling 32 IEPE input Excitation 4 mA 8 mA Compliance voltage 24 V Output Impedance Sensor detection Shortcut 4 V Open 19 V TEDS support IEPE mode only Power Power consumption 2 W Environmental IP rating IP20 Physical Dimensions 82 x 62 x 28 mm Weight 130 g Rev 1593518446 5 10 2 ACC BNC Connector 5 10 2 1 ACC BNC Connector Pinout ACC connector pin out BNC Pin Name Description 1 IN Input 2 GN...

Page 134: ...IOLITE TECHNICAL REFERENCE MANUAL 5 10 2 2 ACC BNC Connector Wiring diagram 5 10 2 2 1 ACC Voltage 5 10 2 2 2 ACC IEPE IOLITE V20 1 134 153 ...

Page 135: ...nternal temperature is also available as a data channel in DEWESoft software under System monitor channels IOLITE 3xMEMS ACC IOLITEw 3xMEMS ACC can be supplied in a waterproof aluminium enclosure with cable glands The enclosure is designed to be mounted outdoor Cables are to be inserted through the cable glands at the installation location and crimped to the male RJ45 connectors Female RJ45 connec...

Page 136: ...RMS Residual noise 2 g range 125 Hz bandwidth 150 µg RMS Offset error 25 mg 10 mg 25 mg 100 mg 30 mg 100 mg Offset temperature drift 20 60 degC 0 15 mg degC 0 02 mg degC 0 15 mg degC 0 75 mg degC 0 2 mg degC 0 75 mg degC Semsitivity temperature drift 20 60 degC 0 01 degC 0 01 degC Linearity error smallest range 0 1 FS 0 1 FS Crossaxis sensitivity 1 1 1 MEMS Inclinometer Typ Accuracy and resolution...

Page 137: ...d the IOLITE Power injector as the first device in the chain IOLITE Power injector 6 1 1 General specifications General specifications Digital interface EtherCAT EtherCAT connector RJ45 Power connectors Wire terminal 2mm jack Erath connectors Wire terminal Wire terminal connector type MC 1 5 3 STF 3 81 Power consumption 500 mW Supply Voltage 12 V 48 V Operating temperature 20 60 degC IP rating IP2...

Page 138: ... V and 48 V is required Connector on the device 2 mm DC power jack PJ 067A 6 1 2 2 IOLITE Power Injector Phoenix MC 1 5 3 Pinout Power in connector pin out Phoenix MC 1 5 3 Pin Name Description 1 V Supply 2 GND Ground 3 EARTH Earth For the power supply an unregulated DC voltage between 12 V and 48 V is required Connector on the device Wire terminal Phoenix MC 1 5 3 GF 3 81 Mating connector for the...

Page 139: ...channel instruments Suggested length of the cable is up to 50 m 6 2 1 General specifications General specifications of the IOLITE Repeater device Digital interface EtherCAT EtherCAT connector RJ45 Power consumption 1200 mW Supply Voltage 12 V 48 V Operating temperature 20 60 degC IP rating IP20 Weight 105 g Housing material Aluminium IOLITE V20 1 139 153 ...

Page 140: ...RJ 45 female Pin Name Description 1 TX_P Transmission 2 TX_N Transmission 3 RX_P Reception 4 DC PoE 5 DC PoE 6 RX_N Reception 7 DC PoE 8 DC PoE 6 2 2 2 EtherNET OUT EtherCAT connector pin out RJ 45 female Pin Name Description 1 TX_P Transmission 2 TX_N Transmission 3 RX_P Reception 4 DC PoE 5 DC PoE 6 RX_N Reception 7 DC PoE 8 DC PoE Hint The power over ethernet is passive This means that there ar...

Page 141: ...t Clamps etc can be found in a separate document which is available for download from our homepage https download dewesoft com download file accessories and sensors technical reference manual pdf In the HW Manuals section click the download link for the Manual for DewesoftX Accessories and Sensors IOLITE V20 1 141 153 ...

Page 142: ...hanges A baud rate by definition means the number of times a signal in a communications channel changes state or varies Example A 2400 baud rate means that the channel can change states up to 2400 times per second This is often confused with the bit rate expressed in bit s which is related but may be different The number of bits per baud is determined by the modulation technique Example If we use ...

Page 143: ... known as cold junction compensation dB The decibel dB is a logarithmic unit that indicates the ratio of a physical quantity usually power or intensity relative to a specified or implied reference level A ratio in decibels is ten times the logarithm to base 10 of the ratio of two power quantities Dewesoft Dewesoft refers to the company DewesoftX refers to the software suite for data acquisition da...

Page 144: ... frequency defined as the number of cycles per second of a periodic signal IRIG B The Inter Range Instrumentation Group IRIG is the standards body of the Range Commanders Council RCC They publish a number of standards e g IRIG time codes The different time codes defined in the Standard have alphabetic designations A B D E G and H IRIG B has a Bit rate of 100 Hz LED A light emitting diode is a semi...

Page 145: ...will take care that data will stay synchronised no matter how long the acquisition runs OS An operating system OS is a set of system software running on a device that manages the system hardware This may refer to the operating system of a PC Windows is required for DewesoftX or to the operating system of the Sirius system PC Sirius systems are typically connected to a Personal Computer which runs ...

Page 146: ...It is a simpler and less accurate version of the Network Time Protocol NTP Synchronization cable These synchronization cables can be used to synchronise several Sirius chassis with each other USB Universal Serial Bus is a specification to establish communication between devices and a host controller usually PCs Sirius systems use a USB connection to connect to a PC Windows A PC operating system by...

Page 147: ...t needs to be calibrated at regular intervals The standard norm across nearly every industry is annual calibration Before your Dewesoft data acquisition system is delivered it is calibrated Detailed calibration reports for your Dewesoft system can be requested We retain them for at least one year after system delivery 9 2 Support Dewesoft has a team of people ready to assist you if you have any qu...

Page 148: ... and we take care that all key products and technologies are registered as trademarks all over the world The Dewesoft name is a registered trademark Product families KRYPTON Sirius DSI DS NET IOLITE and technologies DualCoreADC SuperCounter GrandView are registered trademarks as well When used as the logo or as part of any graphic material the registered trademark sign is used as a part of the log...

Page 149: ...bserved during all phases of operation service and repair of this product Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design manufacture and intended use of the product Dewesoft GmbH assumes no liability for the customer s failure to comply with these requirements All accessories shown in this document are available as an...

Page 150: ... and connector serve as Power Breaker The cable must not exceed 3 meters the disconnect function must be possible without tools Maintenance must be executed by qualified staff only During the use of the system it might be possible to access other parts of a more comprehensive system Please read and follow the safety instructions provided in the manuals of all other components regarding warning and...

Page 151: ...y touching the wiring The product heats during operation Make sure there is adequate ventilation Ventilation slots must not be covered Only fuses of the specified type and nominal current may be used The use of patched fuses is prohibited Prevent using metal bare wires Risk of short circuit and fire hazard DO NOT use the system before during or shortly after a thunderstorm risk of lightning and hi...

Page 152: ...limited to systems and equipment for industrial applications intended to perform safety functions as defined in IEC 61508 with SIL 1 3 The electromagnetic environments encompassed by this product family standard are industrial both indoor and outdoor as described for industrial locations in IEC 61000 6 2 or defined in 3 7 of IEC 61326 1 Equipment and systems intended for use in other electromagnet...

Page 153: ... LV modules IOLITEi 8xLV IOLITEi 8xLV 10V IOLITEi 8xLV TBLOCK IOLITEi 8xLV 10V TBLOCK DIO module IOLITEi 8xDI 4xDO RTD module IOLITE RTD TBLOCK CNT module IOLITE 4xCNT Updated template V21 1 25 2 21 Added devices 16xLV 8xLA 8xSTGS IOLITEi multichannel IOLITEi signal channel IOLITE4xMEMS ACC IOLITE accessories Changed naming of the devices IOLITE V20 1 153 153 ...