SIRIUSi-XHS®
TECHNICAL REFERENCE MANUAL
XCP: Starting with version 1.4., XCP became a very powerful interface protocol in the automotive
industry for data exchange. In the modern age of e-mobility, the required sampling rates are much
higher than ever and 1 GBIT XCP interface allows data transfers with as high as 1 Ms/sec.
3.1.4. Data Acquisition Software Included for Free
All Dewesoft data acquisition systems are bundled with award winning Dewesoft Professional DAQ
software. DewesoftX is the world's most advanced and easy-to-use data acquisition and analysis
software. Dewesoft 's flexibility and power will help you unleash the DAQ system to its full potential and
gives you many advantages over other DAQ systems. Functionalities like plug-and-play, hardware
auto-detection, smart TEDS sensors, advanced storing and data analysis features will take your
measurement and analysis needs to a whole new level.
3.2. System specifications
Power
Power Supply 9 - 48 V DC
Power consumption Typ. 30 W
Environmental
Operating Temperature -10 to 50 °C
Storage Temperature -40 to 85 °C
Humidity 5 to 95 % RH non condensing @ 60 °C
IP rating IP20
Shock & Vibration Shock (EN 60068-2-27:2009)
75 g, 6 ms, half-sine (25x pos./neg in each ahis)
Random Vibration (EN 60721-3-2: 1997 - Class 2M2)
Sweep sinus Vibration (EN 60068-2-6:2008)
Interfaces
Ethernet
1 GbE (XCP, OPC UA) incl. IEEE1588v2 synchronization (PTP)
(RJ45)
USB USB 3.0 (Type C)
CAN CAN 2.0 (DSUB9)
Sync Input/Ouput
Level (Input/Output) TTL compatible
Max. Output Current ±24 mA (±50 mA for 1 sec)
Max. Sync-cable length 100 m (Master/Slave), 200 m (IRIG)
SIRIUSi-XHS® - V21-2
27/52