![DewertOkin C DD-A 1xCB Installation Instructions Manual Download Page 29](http://html1.mh-extra.com/html/dewertokin/c-dd-a-1xcb/c-dd-a-1xcb_installation-instructions-manual_2489902029.webp)
System DD11 / System DD21
Installation
82774 2.0
29
5.2 Installing the DD11 and DD21 lifting columns
Before installing and connecting the DD11/DD21 lifting columns, make sure that you are observing
all of the safety notices found in the "Safety notices to observe during installation" section.
5.2.1 Installing the table base
Use M6 bolts (with strength grade 8.8), as shown in Figure19. The tightening torque must not ex-
ceed 10 Nm.
Figure19
Mounting the table base (dimensions in mm)
A
Base plate
B
M6 bolts (8.8)
C
Foot of the lifting column
B
C
A
Max. 8
60
30
C