6
3 . Pull back the collar on the female quick-connect coupler located
on the compressor.
4 . Push the male connector into the female connector.
5 . Release the female connector.
6 . Grasp hose and pull to ensure couplers are seated.
7 . Adjust regulator to desired pressure.
DISCONNECTING HOSES
WARNING: Firmly grasp the hose when installing or disconnect -
ing to prevent hose whip.
1 . Ensure that the regulated pressure gage reads 0 PSI.
2 . Grasp the hose at the coupler.
3 . Pull back the collar on female quick-connect coupler located on
the compressor.
4 . Pull the male connector out of the female connector.
5 . Release the female connector.
DRAINING THE TANK
WA R N I N G : The tank contains high pressure air. Keep the outlet
of drain away from face and other body parts. Use safety glasses
when draining because debris can be kicked up into face. Use ear
protection because air flow noise is loud when draining.
N O T E : All compressed air systems generate condensate that
accumulates in any drain point (e.g. tanks, filter, aftercoolers, dryers).
This condensate contains lubricating oil and/or substances which
may be regulated and must be disposed of in accordance with local,
state, and federal laws and regulations.
1 . Ensure that the ON/OFF switch is in the OFF position.
2 . Move the compressor into an inclined position so that the drain
valve(s) are at the lowest point This will assist in removing
moisture, dirt, etc. from the tanks.
3 . Place a suitable container under the drain to catch discharge.
move or is difficult to move.
CHECKING AIR FILTER ELEMENT
WA R N I N G : A f t e r c o o l e r, pump head, and surrounding parts are
very hot. Do not touch (see Hot Surfaces on page 4).
1 . Ensure that the unit is off .
2 . Allow the unit to cool.
3 . Unscrew the filter from pump head by turning counter clockwise.
4 . Separate the filter body into two halves.
5 . If the element needs cleaning blow out with air. Replace air filter
assembly if unsure whether element can be cleaned suff i c i e n t l y.
6 . Reconnect the filter body.
7 . Screw the filter into pump head by turning clockwise until the
filter is hand tight.
TURNING THE UNIT ON
Follow the pre-start and start-up procedures in the operating
procedure section.
TURNING THE UNIT OFF
Follow the shut-down procedures in the operating procedures
s e c t i o n .
ADJUSTING THE REGULATOR
1 . Pull the regulator knob out. (For D55155 compressor)
2 . Turn the knob clockwise to increase regulated pressure and
counter clockwise to decrease regulated pressure.
3 . When desired pressure is shown on the regulated pressure gage,
push the knob in to lock it. (For D55155 compressor)
INSTALLING HOSES
WARNING: Firmly grasp the hose when installing or disconnect -
ing to prevent hose whip.
1 . Ensure that the regulated pressure gage reads 0 PSI.
2 . Grasp the hose at the coupler.