CoDe
PossIble CAuse
PossIble solutIon
15
Tank pressure exceeds pressure switch cut-in
pressure
Motor will start automatically when tank pressure drops below
cut-in pressure of pressure switch.
16
Extension cord is wrong length or gauge
Check for proper gauge wire and cord length. Refer to the
extension Cords paragraph in the Installation section.
17
Loose electrical connections
Contact a D
e
WALT factory service center or a D
e
WALT autho-
rized service center.
18
Possible defective motor
Contact a D
e
WALT factory service center or a D
e
WALT autho-
rized service center.
19
Paint spray on internal motor parts
Contact a D
e
WALT factory service center or a D
e
WALT authorized
service center. Do not operate the compressor in the paint spray
area. See flammable vapor warning.
20
Fuse blown, circuit breaker tripped
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit breaker with
higher rating than that specified for our particular branch cir-
cuit.
2. Check for proper fuse. You should use a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or oper-
ate the compressor on its own branch circuit.
21
Restricted air intake filter
Clean or replace air intake filter. Do not operate the air
compressor with the filter removed. Refer to the Air filter
paragraph in the Maintenance section.
22
Defective pilot valve
Replace pilot valve. Contact a D
e
WALT factory service center or a
D
e
WALT authorized service center.