8 / 12

TROUBLESHOOTING

 CONDITION 

CAUSE 

CORRECTION

Heavy top or  

Horn holes plugged. 

Clean.  Ream with non-metallic point. 

bottom pattern 

Obstruction on top or bottom of fluid tip. 

Clean.

 

 

Cap and/or tip seat dirty. 

Clean.

Heavy right or left side pattern 

Left or right side horn holes plugged. 

Clean.  Ream with non-metallic point.

 

 

Dirt on left or right side of fluid tip. 

Clean.

 

 

Remedies for the top-heavy, bottom-heavy,  right-heavy and left-heavy patterns:

 

 

1)  Determine if the obstruction is on the air cap or the fluid tip.  Do this by making  a test spray 

 

 

pattern.  Then, rotate the cap one-half turn and spray another pattern. If the defect is inverted,

 

 

 obstruction is on the air cap.  Clean the air cap as previously instructed.

 

 

2)  If the defect is not inverted, it is on the fluid tip.  Check for a fine burr on the  edge of the fluid tip.   

 

 

Remove with #600 wet or dry sand paper.

 

 

3)  Check for dried paint just inside the opening.  Remove paint by washing with solvent.

Heavy center pattern 

Fluid pressure too high for atomization 

Balance air and fluid pressure.     

 

 

 

   air (pressure feed). 

Increase spray pattern width with

 

 

 

 

   spreader adjustment valve.

 

 

Material flow exceeds air cap's capacity. 

Thin or lower fluid flow.  

 

 

 

 

Spreader adjustment valve set too low. 

Adjust.

 

 

Atomizing pressure too low. 

Increase pressure.

 

 

Material too thick. 

Thin to proper consistency.

Split spray pattern 

Atomization air pressure too high. 

Reduce at transformer or gun.    

 

 

 

Fluid pressure too low (pressure feed only). 

Increase fluid pressure (increases gun

 

 

 

 

handling speed).

 

 

Spreader adjusting valve set too high. 

Adjust.

Jerky or fluttering spray 

*Loose or damaged fluid tip/seat. 

Tighten or replace.

 

 

Material level too low. 

Refill.

 

 

Container tipped too far. 

Hold more upright.

 

 

Obstruction in fluid passage. 

Backflush with solvent.

 

 

Loose or broken fluid tube or fluid inlet nipple. 

Tighten or replace.

 

 

Dry or loose fluid needle packing nut. 

Lubricate or tighten.

Unable to get round spray 

Spreader adjustment screw not seating properly.  Clean or replace.

 

 

Air cap retaining ring loose. 

Tighten.

Will not spray 

No air pressure at gun. 

Check air supply and air lines.

 

 

Internal mix or pressure feed air cap and tip 

Change to proper suction feed air cap and tip.

 

 

   used with suction feed. 

 

 

Fluid pressure too low with internal mix cap and 

Increase fluid pressure at tank.

 

 

   pressure tank.

 

 

Fluid needle adjusting screw not open enough. 

Open fluid needle adjusting screw.

 

 

Fluid too heavy for suction feed. 

Thin material or change to pressure feed.

Excessive overspray 

Too much atomization air pressure 

Reduce pressure.

 

 

Gun too far from work surface. 

Adjust to proper distance.

 

 

Improper stroking (arcing, gun motion too fast). 

Move at moderate pace, parallel towork surface.   

Excessive fog 

Too much, or too fast-drying thinner. 

Remix properly.

 

 

Too much atomization air pressure. 

Reduce pressure.

Dry Spray 

Air pressure too high. 

Reduce air pressure.

 

 

Gun tip too far from work surface. 

Adjust to proper distance.

 

 

Gun motion too fast. 

Slow down.

 

 

Gun out of adjustment 

Adjust.

Fluid leaking from packing nut 

Packing nut loose. 

Tighten, do not bind needle.

 

 

Packing worn or dry 

Replace or lubricate.

Fluid leaking or dripping from  

Packing nut too tight. 

Adjust.

front of pressure feed gun 

Dry packing.   

Lubricate.

 

 

Fluid tip or needle worn or damaged. 

Replace tip & needle with lapped sets.

 

 

Foreign matter in tip. 

Clean.

 

 

Fluid needle spring broken. 

Replace.

 

 

Wrong size needle or tip. 

Replace.

 Runs and sags 

Too much material flow. 

Adjust gun or reduce fluid pressure. 

  

Material too thin. 

Mix properly or apply light coats.

  

Gun tilted on an angle, or gun motion too slow.    Hold gun at right angle to work and adapt to   

  

 

  proper gun technique 

 

 

  

 

 

 Thin, sandy coarse finish  

Gun too far from surface. 

Check distance.  Normally approx. 8".

 drying before it flows out 

  

Too much air pressure. 

Reduce air pressure and check spray pattern. 

  

Improper thinner being used. 

Follow paint manufacturer's mixing instructions.

  *Most common problem.

Summary of Contents for SB-2-545-L

Page 1: ...EN SB 2 545 L 5 2016 1 12 SERVICE MANUAL OPERATION MANUAL HVLP PRESSURE SIPHON FEED SPRAYGUN...

Page 2: ...terials Technology WN8 9PN UK Lodging of Technical file 11 May 16 Signed for and on behalf of Finishing Brands UK Ltd Machinery Directive 2006 42 EC ATEX Directive 2014 34 EU by complying with the fol...

Page 3: ...VE EQUIPMENT Toxic vapors When sprayed certain materials may be poisonous create irritation or be otherwise harmful to health Always read all labels and safety data sheets for the material before spra...

Page 4: ...e g 14 1 4 mm 10 Airvalve housing seal SP 612 K 1 11 Spindle 1 12 Trigger Stud and Screw SP 617 CR K 1 13 Connector SP 611 K 1 14 Plug JGA 132 1 15 Fluid Inlet Connector and seal SP 636 K 1 17 Retain...

Page 5: ...ressure in the supply lines or if using QD system disconnect from airline and fluid line 2 Remove air cap 1 and clean If any of the holes in the cap are blocked with coating material use a toothpick t...

Page 6: ...Using Service Tool SPN 7 engage groove behind the Valve Seat 6 Remove Valve Seat 7 Push out the Front Airvalve Seal with a finger 8 Turn the Gun upside down and let the Seal fall out 9 Fit New Front...

Page 7: ...strument 14 Fit new Seal to Service Tool 15 Fit Seal to Housing 10 16 Replace Spindle 11 17 Replace Valve Spring and attach Housing 10 18 Tighten Housing 19 Fit Needle 9 20 Fit Spring 8 and Knob 7 21...

Page 8: ...or loose fluid needle packing nut Lubricate or tighten Unable to get round spray Spreader adjustment screw not seating properly Clean or replace Air cap retaining ring loose Tighten Will not spray No...

Page 9: ...8 peel Too much material coarsely atomized Increase air pressure or decrease fluid pressure Air pressure too low Increase air pressure or reduce fluid pressure Improper thinner being used Follow paint...

Page 10: ...ed TSC 591Stainless Steel Cup KB 555 Aluminum KB 545 SS S S 2 qt Pressure Feed Cup With Regulator TGC 545 Aluminum TLC 555 Non stick Lined TGC 595 Stainless Steel Siphon Cups Provides greater degree o...

Page 11: ...EN SB 2 545 L 5 2016 11 12 NOTES...

Page 12: ...r in innovative finishing technologies For technical assistance or to locate an authorized distributor contact one of our international sales and customer support locations USA Canada info carlisleft...

Page 13: ...ES SB 2 545 L 5 2016 ES 1 12 MANUAL DE OPERACI N COMPACT PISTOLA PULVERIZADORA POR PRESI N POR SIF N HVLP MANUAL DE SERVICIO...

Page 14: ...i n de Ficha t cnica 11 May 16 Directiva de m quinas 2006 42 CE Directiva ATEX 2014 34 EU ya que es conforme con las siguientes normas armonizadas y documentos estatutarios EN ISO 12100 2010 Seguridad...

Page 15: ...Al pulverizarse ciertos materiales pueden ser t xicos crear irritaci n o ser da inos para la salud de otra forma Lea siempre todas las etiquetas y hojas de datos de seguridad del material antes de pu...

Page 16: ...Gatillo espiga y tornillo SP 617 CR K 1 13 Conector SP 611 K 1 14 Tap n JGA 132 1 15 Entrada de fluido Conector y junta SP 636 K 1 17 Ret n y juntas SPK 102 K 1 18 Kit de clip junta y perno paq de 5 G...

Page 17: ...PREVENTIVO 1 Cierre el suministro de aire y recubrimiento y alivie la presi n en los manguitos o si utiliza el sistema QD descon ctelo del manguito de aire y de fluido 2 Retire el casquillo de aire 1...

Page 18: ...asiento de la v lvula 6 Retire el asiento de la v lvula 7 Haga salir la junta delantera de la v lvula de aire empujando con el dedo 8 Ponga la pistola boca abajo y deje que se caiga la junta 9 Instale...

Page 19: ...ienta de mantenimiento 15 Coloque la junta en el alojamiento 10 16 Vuelva a colocar el v stago 11 17 Vuelva a colocar el muelle de la v lvula y vuelva a colocar en el alojamiento 10 18 Apriete el aloj...

Page 20: ...de trabajo Carrera indebida formaci n de arco el desplazamiento de la pistola es muy r pido Reduzca la presi n Ajuste hasta la distancia debida Despl cese a ritmo moderado paralelo a la superficie de...

Page 21: ...ire muy baja Se est empleando un diluyente inadecuado No se ha mezclado debidamente el material Superficie spera aceitosa o sucia Verifique la distancia Normalmente aprox 8 pulg Aumente la presi n de...

Page 22: ...i n de 1 cuarto de gal n 3 8 de pulg NPS F tapa con cerrojo de leva Requiere del kit del regulador de aire KK 4980 Cubeta de aluminio TLC 576 forrada con revestimiento antiadherente y Cubeta de acero...

Page 23: ...ES SB 2 545 L 5 2016 ES 11 12 NOTAS...

Page 24: ...olog as de acabados pulverizados innovadores Para asistencia t cnica o para localizar un distribuidor autorizado p ngase en contacto con uno de nuestros centros internacionales de ventas y apoyo al cl...