background image

11 — ENG

TROUBLESHOOTING GUIDE (Continued)

CORRECTION

CAUSE

Possible defect in safety valve.

Knocking Noise

Compressor is not supplying
enough air to operate acces-
sories.

Prolonged excessive use of air.

Decrease amount of air usage.

Hole in hose.

Remove and clean, or replace.

Air leaks.

Tighten fittings.  (See Air Leaks Section of Trou-
bleshooting Guide.)

Motor will not run.

Check valve restricted.

Check and replace.

Check the accessory air requirement.  If it is higher
than the SCFM or pressure supplied by your air
compressor, you need a larger compressor.

Compressor is not large enough for air
requirement.

Defective check valve.

Remove and clean, or replace.

Operate safety valve manually by pulling on ring.  If
valve still leaks, it should be replaced.

Air leak from safety valve.

PROBLEM

Motor will start automatically when tank pressure
drops below “cut-in” pressure of pressure switch.

Tank pressure exceeds pressure
switch “cut-in” pressure.

Check for proper gauge wire and cord length.

Wrong gauge wire or length of exten-
sion cord.

Loose electrical connections.

Check wiring connection inside pressure switch
and terminal box area.

Remove and clean, or replace.

Check valve stuck open.

Paint spray on internal motor parts.

Have checked at an Authorized Warranty Service
Center.  Do not operate the compressor in the paint
spray area.  See flammable vapor warning.

Possible defective motor.

Have checked at an Authorized Warranty Service
Center.

1.

Check fuse box for blown fuse and replace, if
necessary.  Reset circuit breaker. Do not use a
fuse or circuit breaker with higher rating than
that specified for your particular branch circuit.

2.

Check for proper fuse.

3.

Check for low voltage conditions and/or proper
extension cord.

4.

Disconnect the other electrical appliances from
circuit or operate the compressor in its own
branch circuit.

Fuse blown, circuit breaker tripped.

Damaged regulator.

Replace regulator.

Regulator knob has continuous
air leak. Regulator will not shut
off at air outlet.

Summary of Contents for FAC1025

Page 1: ...Phase Minimum Branch Circuit Requirement Fuse Type Amperage at Max Load Tank Size SPECIFICATION CHART FAC1025 1 3 7 2 7 100 PSI 125 PSI 1 7 8 1 1 4 120 60 1 15AMPS Quick Acting 10AMPS 2 5 Gallon A ci...

Page 2: ...URY OR LOSS OF LIFE Call our Toll Free Number 1 800 888 2468 Ext 2 then 1 to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs When orderi...

Page 3: ...tact the nearest Authorized Warranty Service Center that provides on site service calls for service call arrangement o If the purchaser does not receive satisfactory results from the Authorized Warran...

Page 4: ...MAKE ANY MODIFICATIONS TO THE TANK or its attachments Never attempt to repair a damaged or leaking tank Replace with a new tank The tank is designed to withstand specific operating pressures NEVER MAK...

Page 5: ...ctly or from a breathing device connected to the compressor WORK IN AN AREA equipped WITH GOOD CROSS VENTILATION Read and FOLLOW THE SAFETY INSTRUCTIONS provided on the label or safety data sheet FOR...

Page 6: ...ressure drops to approximately 100 PSI the motor will restart automatically The low pressure at 1 Set the ON OFF switch to OFF and unplug the cord 2 Review the Operating Procedures section page 9 Be s...

Page 7: ...n the compressor in good condition no longer than 50 feet 14gauge AWG orlarger Wiresizeincreasesas gaugenumberdecreases 12AWG 10AWGand 8AWGmayalsobeused DONOTUSE16OR18 AWG Location of the Air Compress...

Page 8: ...he following break in instructions are not closely followed The air compressor is equipped with a cord having a grounded wire with an appropriate grounding plug The plug must be used with an outlet th...

Page 9: ...lever to AUTO and allow tank pressuretobuild Motorwillstopwhentankpressure reaches cut out pressure 4 Opentheregulatorbyturningitclockwise Adjustthe regulator to the correct pressure setting Your com...

Page 10: ...fective pressure release valve Defective check valve Air leaks at pressure switch release valve Remove and replace the release valve Air leaks in air tank or at air tank welds DO NOT DRILL INTO WELD O...

Page 11: ...sure exceeds pressure switch cut in pressure Check for proper gauge wire and cord length Wrong gauge wire or length of exten sion cord Loose electrical connections Check wiring connection inside press...

Page 12: ...wn CHECKVALVE Not Shown ISOLATOR DESCRIPTION PART NUMBER AIR CHUCK SSH 20 REGULATOR CAC 4296 1 TANK PRESSURE GAUGE C GA 345 B OUTLET PRESSURE GUAGE C GA 345 B SAFETY VALVE TIA 4150 DRAIN VALVE SS 2707...

Page 13: ...13 ENG AIR COMPRESSOR DIAGRAM...

Page 14: ...eal Head gasket Valve plate assembly O ring Outlet tube Rod assembly Screw 3 8 16 x 1 25 LG hex socket flat head Cylinder sleeve Endbell assembly Timing belt Pump isolator Shroud right Shroud left Scr...

Page 15: ...15 ENG NOTES...

Page 16: ...68 Ext 2 then 1 to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center...

Reviews: