background image

6 — ENG

GLOSSARY

 which the motor automatically re-starts is called "cut-in
pressure."

CUT-OUT PRESSURE: 

 When you turn on your air com-

pressor and it begins to run, air pressure in the air tank
begins to build. It builds to approximately 125 PSI before the
motor automatically shuts off .The high pressure at which
the motor shuts off is called "cut-out pressure."

SCFM or CFM: 

 Standard Cubic Feet per Minute; a unit of

measurement of air delivery.

PSIG or PSI: 

 Pounds per square inch gauge.

CUT-IN PRESSURE: 

 While the motor is off, air tank

pressure drops as you continue to use your accessory.
When the tank pressure drops to approximately 100 PSI
the motor will restart automatically. The low pressure at

1. Set the "ON/OFF" switch to "OFF" and unplug the

cord.

2. Review the "Operating Procedures" section (page 9).

Be sure to drain the water from the air tank.

When you have finished using the air compressor:

STORAGE

DUTY CYCLE

All DeVilbiss Air Power manufactured air compressors
should be operated on not more than a 50% duty cycle.
This means an air compressor that pumps air more than

3. Protect the electrical cord and air hose from damage by

winding them loosely around the air compressor.

4. Store the air compressor in a clean and dry location.

50% of one hour is considered misuse, because the air
compressor is undersized for the required air demand.
Maximum compressor pumping time per hour is 30 min-
utes.

Summary of Contents for FAC1025

Page 1: ...Phase Minimum Branch Circuit Requirement Fuse Type Amperage at Max Load Tank Size SPECIFICATION CHART FAC1025 1 3 7 2 7 100 PSI 125 PSI 1 7 8 1 1 4 120 60 1 15AMPS Quick Acting 10AMPS 2 5 Gallon A ci...

Page 2: ...URY OR LOSS OF LIFE Call our Toll Free Number 1 800 888 2468 Ext 2 then 1 to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs When orderi...

Page 3: ...tact the nearest Authorized Warranty Service Center that provides on site service calls for service call arrangement o If the purchaser does not receive satisfactory results from the Authorized Warran...

Page 4: ...MAKE ANY MODIFICATIONS TO THE TANK or its attachments Never attempt to repair a damaged or leaking tank Replace with a new tank The tank is designed to withstand specific operating pressures NEVER MAK...

Page 5: ...ctly or from a breathing device connected to the compressor WORK IN AN AREA equipped WITH GOOD CROSS VENTILATION Read and FOLLOW THE SAFETY INSTRUCTIONS provided on the label or safety data sheet FOR...

Page 6: ...ressure drops to approximately 100 PSI the motor will restart automatically The low pressure at 1 Set the ON OFF switch to OFF and unplug the cord 2 Review the Operating Procedures section page 9 Be s...

Page 7: ...n the compressor in good condition no longer than 50 feet 14gauge AWG orlarger Wiresizeincreasesas gaugenumberdecreases 12AWG 10AWGand 8AWGmayalsobeused DONOTUSE16OR18 AWG Location of the Air Compress...

Page 8: ...he following break in instructions are not closely followed The air compressor is equipped with a cord having a grounded wire with an appropriate grounding plug The plug must be used with an outlet th...

Page 9: ...lever to AUTO and allow tank pressuretobuild Motorwillstopwhentankpressure reaches cut out pressure 4 Opentheregulatorbyturningitclockwise Adjustthe regulator to the correct pressure setting Your com...

Page 10: ...fective pressure release valve Defective check valve Air leaks at pressure switch release valve Remove and replace the release valve Air leaks in air tank or at air tank welds DO NOT DRILL INTO WELD O...

Page 11: ...sure exceeds pressure switch cut in pressure Check for proper gauge wire and cord length Wrong gauge wire or length of exten sion cord Loose electrical connections Check wiring connection inside press...

Page 12: ...wn CHECKVALVE Not Shown ISOLATOR DESCRIPTION PART NUMBER AIR CHUCK SSH 20 REGULATOR CAC 4296 1 TANK PRESSURE GAUGE C GA 345 B OUTLET PRESSURE GUAGE C GA 345 B SAFETY VALVE TIA 4150 DRAIN VALVE SS 2707...

Page 13: ...13 ENG AIR COMPRESSOR DIAGRAM...

Page 14: ...eal Head gasket Valve plate assembly O ring Outlet tube Rod assembly Screw 3 8 16 x 1 25 LG hex socket flat head Cylinder sleeve Endbell assembly Timing belt Pump isolator Shroud right Shroud left Scr...

Page 15: ...15 ENG NOTES...

Page 16: ...68 Ext 2 then 1 to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center...

Reviews: