DEVO-7 Page 57 of 170
Press DN to enter ST1 and ST2 after finish, setting steps are the same as NOR
MODE setting
Press EXT to finish.
3.9 Governor
Before setup this function, “Governor” should be set and activated in “Device output”
interface. (Refer to 2.9 Device Output)
It is possible to set Governor control rate in various flight modes separately. Please
setup the Governor for the desired retation speed. The transmitter display data is only
for percentage reference. The real rotation speed refer to Governor.
Press “ENT” key to enter Main Menu, press UP or DN until “FUNCTION” flash , and
then Press “ENT” key to enter Function Menu; Press UP or DN button until
“
GOVER
”
becomes flash. Press ENT to enter the interface of MODE Menu and adjustable Value
options. There are “Normal mode”,”ST1”,“ST2”, “Throttle Hold” 4 options available.
NORM setting: The picture as below. Press R or L to set the value. Press R to
decrease, the minimum is -125%; Press L to increase, the maximum is +125%.