Metering cluster - Manufacture Specific Attributes
Develco Manufacture code is 0x1015.
Table 1 : Formatting Attribute Set (Manufacture Specific)
Identifier
Name
Type
Range
Access
Default
Man./Opt.
0x0300
PulseConfiguration
Unsigned 16-
bit integer
0x0000
–
0xFFFF
Read/
Write
0x03E8
O
0x0301
CurrentSummation
Unsigned 48
bit integer
0x000000 -
0xFFFFFFF
Write
Only
0x0000
O
0x0302
InterFaceMode
Enum16
0x0000
–
0xFFFF
Read/
Write
0x0000
4.1.4.1.1
PulseConfiguration
PulseConfiguration
represents the number of pulses the meter outputs per unit.
Default value is 1000 imp/kWh, 0x03E8 = 1000 dec.
4.1.4.1.2
CurrentSummation
CurrentSummation
represents the present value for current summation delivered send to the display.
The value must be scaled according to divider and multiplier.
MFG attribute id 0x0302
–
Interface mode
Attribute value
Description
0x0000
Pulse counting on a Electricity meter
–
Unit KWh
Typically LED or IR probe is used.
0x0001
Pulse counting on a Gas meter
–
Unit m3
Typically S0 or Pulse probe is used
0x0002
Pulse counting on a Water meter
–
Unit m3
Typically S0 or Pulse probe is used
0x0100
Kamstrup KMP protocol
–
IR communication using IR probe
0x0101
Not supported - Linky protocol
0x0102
DLMS-COSEM - IEC62056-21 mod A
IR communication using IR probe.