External Meter Interface
–
ZHEMI-101
–
Technical manual
Develco Products A/S
Olof Palmes Allé 40
http://develcoproducts.com
DK-8200 Aarhus N
13
Example: Preset value = 0,570 kWh
Divider = 1000
Multiplier = 1
That give a
CurrentSummation
value of 570
It is important that the
PulseConfiguration
attribute has been configured correctly before sending the
CurrentSummation
setting because
PulseConfiguration
is used when calculating the total amount of detected
pulses.
4.1.5
Metering cluster for EP 0x40 and 0x41
End point 0x40 and 0x41 is created runtime when the meter is configured to interface mode P1
–
“Dutch Smart Meter
Standard” version 4.0. Endpoint 0x40 is mapped to MBus channel 1, and endpoint 0x41 is mapped to MBus channel 2.
ZigBee SE metering cluster, is listed. Refer to the ZigBee specification of the metering cluster.
4.1.5.1
0x00 Reading Information attribute set
Id#
Name
Type
Range
SE Req.
Note
0x00
CurrentSummationDelivered
Uint48
Type
range
M
Set based on “
0-n:24.2.1
”
0x07
ReadingSnapshotTime
UTC
Type
range
O
Set based on timestamp of
“
0-n:24.2.1
”
0x14
SupplyStatus
Enum8
O
Set based on “
0-1:24.4.0
”
'0': SUPPLY_OFF
'1': SUPPLY_ON
'2': SUPPLY_OFF_ARMED
The current standard IR probe supports 300-1200 BAUD.
IR probe supporting 9600 BAUD is available on request.
0x0103
P1 dutch standard
–
DSMR 2.3 version
0x0104
P1 dutch standard
–
DSMR 4.0 version