PIVIN & DRAPEAU inc.
22/27
3.6 Photocell beam wiring
:
Primary protection against entrapment
To reduce the risk of entrapment, you must install photocell beam beams that shall
cover the area along the gate’s run as shown in fig. 3.6. To comply with UL 325
standard, use Omron E3K-R10K4.
Fig. 3.6
For electrical wirings of the photocell, see electrical drawing BC14-TRS-EL (three
phases power supply) or BC14-MN-EL (single phase power supply).
3.7 Safety edges wiring
:
Secondary protection against entrapment
To reduce the risk of entrapment, you must install two safety edges, one at each
end of the gate, as shown in fig. 3.6. To comply with UL 325 standard, use Miller
Edge #ME123.
Also, it is the sole responsibility of the installer to add one or more safety edges
where the risk of entrapment and obstruction exists, such as the leading edge,
trailing edge, and post mounted both inside and outside of the gate.
For electrical wirings of the safety edges, see electrical drawing BC14-TRS-EL
(three phases power supply) or BC14-MN-EL (single phase power supply).