Customer Documentation DEV 5071
Copyright DEV Systemtechnik GmbH 2007-2017
31
5.4.4.2 Power Supply Output
If "Power Supply Output" is selected via the radio button on the left side of
the Control Tab, the power supply output panel appears on the right side. It
consists of two sections:
1) In the "Status" section measured output voltage and the measured
output current of the device are shown.
2) In the "Setup" section, the output voltage of the device can be modified
and the maximum output current can be adjusted.
The value for the maximum output current serves as a threshold for
alarming purposes, only. I.e. the CPU module sums up the measured
currents of the installed power supply modules and compares it against
this value. If the sum exceeds the value, an alarm is triggered. Note that
values above 100 A can be entered as integer value (e.g. "163" instead
of "162.9"), only.
Please refer to chapter 4.3.1 providing information on the meaning of the
values and on the limits for adjusting the two values!
Changes on the values become effective after the Save button was
operated (in Local Mode!).