Start procedure
Operation
© 2007
29
3
Starting
z
Engine is controlled electronically, e.g. delivered
with electronic engine control EMR3 and the
necessary function configurations.
z
Separate engine from driven devices by discon-
necting if possible.
z
Do not run up the engine immediately to high
idling speed / full load operation from cold.
z
If the starter is connected to the EMR3 by a relay,
z
the maximum starting time is limited by the
EMR3.
–
The pause between two start attempts is pre-
set by the EMR3.
If the touch start function is programmed, a
short start command with the ignition key in
position 2 or a start button, if available, suffic-
es.
Before starting, make sure that nobody is
standing in the immediate vicinity of the en-
gine or work machine.
After repair work: Check that all guards
have been replaced and that all tools have
been removed from the engine.
When starting with the flame glow plug/
glow plug/heating flange system do not use
any other starting aid (e.g. injection with
start pilot). Risk of accident!
If the engine does not start properly when
the heating flange is automatically actuated
(starter does not receive current as a result
of a fault in the equipment/customer electri-
cal control system) the starting procedure
must be abandoned (set the ignition switch
to OFF, disconnect the power supply to the
heating flange).
–
The start is then continued automatically by
the EMR3.
–
The EMR3 can be programmed for special
applications by data record so that the con-
trol unit can also carry out further start at-
tempts automatically if the engine fails to
start.
If the engine does not start and the error
lamp blinks, the EMR3 system has activat-
ed the start lock to protect the engine.
The start lock is released by switching off
the system with the ignition key for about 30
seconds.
Separate the engine if possible by disen-
gaging driven units.
Do not actuate the starter for more than
20 seconds. If the engine does not start up,
wait for one minute and then repeat the
starting process.
If the engine does not start up after two at-
tempts, determine the cause as per fault ta-
ble (
62
).
Do not run up the engine immediately to
high idling speed / full load operation from
cold.
OBJ_DOKU-12638-001.fm Seite 29 Mittwoch, 22. August 2007 9:25 09