Seite 88
© 06/02
EMR 2
Diagnostic Button and
Fault Indicator Lamp
1
2
3
4
5
6
7
8
9
10
11
12
12
On
Off
Time
2 s
On
Off
Time
© 06/02
Key switch (terminal 15)
On
Off
Time
On
Off
Time
Fault indicator lamp
Case a)
Lamp
extinguished
after 2 s: there is no active fault
2 s
1 s
1 s
Case b)
Lamp
flashes
after 2 s: there is at least one serious fault.
the engine cannot be started.
Case c)
Continuous light
: there is at least one fault.
On
Off
Time
2 s
Case d)
As case c), only with
monitoring delay
t
v
dependent on
selected setting.
t
v